Background: Radiation exposure in the electrophysiology lab is a major occupational hazard to the electrophysiologists. A catheter localization system (MediGuide Technology, St. Jude Medical Inc., St. Paul, MN, USA) allows the integration of electroanatomical mapping and x-ray imaging, and has been shown to be effective in reducing radiation exposure during several electrophysiological procedures. We intended to evaluate the feasibility of this catheter tracking system to guide transseptal (TS) access.

Methods: The feasibility of performing TS puncture with MediGuide (MDG) was assessed in a prospective observational study in 16 patients undergoing radiofrequency ablation for atrial fibrillation. These patients were compared to 16 matched patients undergoing similar procedures during the same time frame using conventional approach. There were no differences in mean age, gender distribution, and body mass index between the two groups. Total duration of fluoroscopic exposure during TS puncture was compared between the two groups.

Results: All patients underwent successful TS puncture. Fluoroscopy time for double TS puncture using the MDG system was significantly lower than the control group (0.48 ± 0.17 minutes vs. 5.9 ± 0.65 minutes; P < 0.0001). No major complications occurred during the procedures in either group.

Conclusions: TS puncture can be successfully performed using MDG, and results in significant reduction in radiation exposure.

Download full-text PDF

Source
http://dx.doi.org/10.1111/pace.12617DOI Listing

Publication Analysis

Top Keywords

radiation exposure
12
catheter tracking
8
tracking system
8
patients undergoing
8
puncture
6
feasibility transseptal
4
transseptal puncture
4
puncture nonfluoroscopic
4
nonfluoroscopic catheter
4
system
4

Similar Publications

Cardiac Positron Emission Tomography (PET) can be used for the assessment of myocardial perfusion. Compared to other cardiac imaging techniques, notably Single Photon Emission Computer Tomography (SPECT), cardiac PET offers superior image resolution, higher accuracy, quantitative measures of myocardial perfusion, lower radiation exposure, and shorter image acquisition time. However, PET tends to be costlier and less widely available than SPECT due to the specialized equipment needed for generating the necessary radiotracers.

View Article and Find Full Text PDF

Coronary artery disease (CAD) remains a leading cause of morbidity and mortality worldwide, necessitating advancements in diagnostic techniques. Coronary CT angiography (CCTA) has emerged as a pivotal non-invasive tool for evaluating coronary artery anatomy and detecting atherosclerotic plaque burden with high spatial resolution. This review explores the evolution of CCTA, highlighting its technological advancements, clinical applications, and challenges.

View Article and Find Full Text PDF

Cannabidiol Ameliorates Doxorubicin-Induced Myocardial Injury via Activating Hippo Pathway.

Drug Des Devel Ther

January 2025

School of Basic Medicine, Jiamusi University, Jiamusi, Heilongjiang, 154000, People's Republic of China.

Background: Doxorubicin (DOX) is a chemotherapeutic agent widely used for cancer treatment and has non-negligible cardiotoxicity. Some previous studies have reported that cannabidiol (CBD) has cardioprotective effects. In this study, we evaluated the protective effects of CBD against DOX-induced cardiomyocyte injury, and explored the downstream molecular mechanism.

View Article and Find Full Text PDF

Purpose: This study evaluated beam quality and radiation dosimetry of a CT scanner equipped with a novel detector and filtration technology called PureVision Optics (PVO). PVO features miniaturized electronics, a detector cut with microblade technology, and increased filtration in order to increase x-ray detection and reduce image noise.

Methods: We assessed the performance of two similar 320-detector CT scanners: one equipped with PVO and one without.

View Article and Find Full Text PDF

The coupling effect of gamma-ray radiation and 532 nm nanosecond laser radiation on optical coatings and substrates was investigated. Fused silica and S-BSL7 glass with 532 nm high reflectivity (HR) coatings were irradiated using Co gamma-ray source at a dose rate of 1 Gy/s for a total dose of 1-500 kGy. After irradiation, the samples were subjected to raster scan testing using a laser with a pulse width of approximately 8.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!