One goal of cardiac research is to perform numerical simulations to describe/reproduce the mechanoelectrical function of the human myocardium in health and disease. Such simulations are based on a complex combination of mathematical models describing the passive mechanical behavior of the myocardium and its electrophysiology, i.e., the activation of cardiac muscle cells. The problem in developing adequate constitutive models is the shortage of experimental data suitable for detailed parameter estimation in specific functional forms. A combination of shear and biaxial extension tests with different loading protocols on different specimen orientations is necessary to capture adequately the direction-dependent (orthotropic) response of the myocardium. In most experimental animal studies, where planar biaxial extension tests on the myocardium have been conducted, the generated shear stresses were neither considered nor discussed. Hence, in this study a method is presented which allows the quantification of shear deformations and related stresses. It demonstrates an approach for experimenters as to how the generation of these shear stresses can be minimized during mechanical testing. Experimental results on 14 passive human myocardial specimens, obtained from nine human hearts, show the efficiency of this newly developed method. Moreover, the influence of the clamping technique of the specimen, i.e., the load transmission between the testing device and the tissue, on the stress response is determined by testing an isotropic material (Latex). We identified that the force transmission between the testing device and the specimen by means of hooks and cords does not influence the performed experiments. We further showed that in-plane shear stresses definitely exist in biaxially tested human ventricular myocardium, but can be reduced to a minimum by preparing the specimens in an appropriate manner. Moreover, we showed whether shear stresses can be neglected when performing planar biaxial extension tests on fiber-reinforced materials. The used method appears to be robust to quantify normal and shear deformations and corresponding stresses in biaxially tested human myocardium. This method can be applied for the mechanical characterization of any fiber-reinforced material using planar biaxial extension tests.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10439-015-1281-zDOI Listing

Publication Analysis

Top Keywords

biaxial extension
16
extension tests
16
shear stresses
16
shear deformations
12
biaxially tested
12
tested human
12
human myocardium
12
planar biaxial
12
quantification shear
8
deformations corresponding
8

Similar Publications

Background: Interspinous devices were introduced in the field of spine surgery as an alternative to traditional pedicle screw fixation in selected patients for treatment of spinal stenosis and fixation. These devices designs have evolved from non-fixated extension blocks to sophisticated interspinous fixation devices (IFDs). There is an absence of literature comparing the biomechanical fixation strength of different IFD plate designs and the role of set screw locking systems.

View Article and Find Full Text PDF

A viscoelastic constitutive framework for aging muscular and elastic arteries.

Acta Biomater

October 2024

Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA; Division of Biomedical Engineering and Imaging Sciences, Department of Biomedical Engineering, King's College London, UK. Electronic address:

The evolution of arterial biomechanics and microstructure with age and disease plays a critical role in understanding the health and function of the cardiovascular system. Accurately capturing these adaptative processes and their effects on the mechanical environment is critical for predicting arterial responses. This challenge is exacerbated by the significant differences between elastic and muscular arteries, which have different structural organizations and functional demands.

View Article and Find Full Text PDF

Dynamic biaxial loading of vascular smooth muscle cell seeded tissue equivalents.

J Mech Behav Biomed Mater

September 2024

Department of Biomedical Engineering, Yale University, New Haven, CT, USA. Electronic address:

An intricate reciprocal relationship exists between adherent synthetic cells and their extracellular matrix (ECM). These cells deposit, organize, and degrade the ECM, which in turn influences cell phenotype via responses that include sensitivity to changes in the mechanical state that arises from changes in external loading. Collagen-based tissue equivalents are commonly used as simple but revealing model systems to study cell-matrix interactions.

View Article and Find Full Text PDF

The biaxial compression experiments of rock-like materials with two flaws are carried out under different flaw inclination angle, rock bridge ligament angle, lateral stress. The experimental studies show that crack propagation modes of rock-like material are as follows: wing crack through mode (Y mode), shear crack through mode (J mode), mixed crack through mode (wing shear JY mode), longitudinal extension of crack and transverse shear splitting. prefabricated fractured rock specimens have experienced the closing stage of prefabricated fractures, the elastic deformation stage, the generation and expansion of cracks (or plastic strengthening), and the residual loading stage.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!