Metal fume fever and polymer fume fever.

Clin Toxicol (Phila)

Division of Medical Toxicology, Drexel University College of Medicine, Philadelphia, PA , USA.

Published: May 2015

Introduction: Inhalational exposure to metal-containing fumes generated by welding and related processes may result in the development of the clinical syndrome known as "metal fume fever." Polymer fume fever is a separate and distinct but related disorder that has been associated with inhalational exposure to specific fluorinated polymer products, such as polytetrafluoroethylene or Teflon(®). We undertook a review of the peer-reviewed medical literature as it relates to these two disease entities in order to describe their epidemiology, pathophysiology, clinical presentation, diagnosis, treatment, prevention, and prognosis.

Methodology: We performed a search of the PubMed ( www.pubmed.com ) and Ovid MEDLINE (ovidsp.tx.ovid.com) databases for keywords "metal fume fever," "polymer fume fever," and "fume fever," covering the period 1946 to September 2014, which resulted in a total of 141 citations. Limiting the search to articles published in the English language yielded 115 citations. These 115 articles were manually reviewed for relevance. In addition, the reference lists in each article retrieved were reviewed for additional relevant references. This left 48 relevant citations.

Epidemiology: Metal fume fever occurs most commonly as an occupational disease in individuals who perform welding and other metal-joining activities for a living. It is estimated that 1,500-2,500 cases of metal fume fever occur annually in the United States. Polymer fume fever was initially identified as an occupational disease but increased regulations have resulted in decreased incidence in the occupational setting. Overheating of Teflon(®)-coated cookware is one of the more common mechanisms for exposure.

Pathophysiology: While the precise pathophysiology associated with the development of metal fume fever is yet to be elucidated, suggested pathophysiologic mechanisms include pro-inflammatory cytokine release, neutrophil activation, and oxygen radical formation. The pathophysiologic mechanism for polymer fume fever has not been definitively elucidated but may involve similar mechanisms to those proposed for metal fume fever.

Clinical Presentation: Metal fume fever typically presents with generally non-specific complaints including influenza-like symptoms, fever, shaking chills, arthalgias, myalgias, headache, and malaise. Onset of symptoms typically occurs 4-10 h following the exposure to metal-containing fumes. While metal fume fever is typically benign and self-limited, severe cases of the disease have been reported. In patients with ongoing metal fume exposure over the course of a workweek, tachyphylaxis occurs resulting in improvement in symptoms over the course of the workweek and maximal symptoms occurring after an exposure-free period such as a weekend. The clinical presentation of polymer fume fever is indistinguishable from metal fume fever, with an exposure history being necessary to distinguish the two entities.

Diagnosis: Chest radiographs are typically normal in cases of metal fume fever and polymer fume fever; however, mild vascular congestion may be demonstrated and severe cases may feature diffuse patchy infiltrates. Laboratory studies are typically not necessary but may demonstrate leukocytosis with leftward shift or an elevated erythrocyte sedimentation rate.

Treatment: The primary treatment for both metal fume fever and polymer fume fever is supportive and directed at symptom relief. Oral hydration, rest, and the use of antipyretics and anti-inflammatory medications (e.g., non-steroidal anti-inflammatory drugs and aspirin) are recommended. A careful workplace exposure assessment analysis conducted by an occupational medicine specialist or clinical toxicologist in concert with a qualified industrial hygienist should be performed.

Prevention: A careful workplace exposure assessment including measurement of ambient zinc and other metal (e.g., chrome, nickel, copper and manganese) fume concentrations or concentrations of fluorocarbon polymer decomposition products at different locations within the workplace should be performed.

Prognosis: Metal fume fever is typically a benign and self-limited disease entity that resolves over 12-48 h following cessation of exposure.

Conclusions: Metal and polymer fume fevers generally follow a benign course with spontaneous resolution of symptoms, though both have the potential to be serious, especially in those with significant preexisting cardiorespiratory disease.

Download full-text PDF

Source
http://dx.doi.org/10.3109/15563650.2015.1013548DOI Listing

Publication Analysis

Top Keywords

fume fever
68
metal fume
48
polymer fume
32
fume
23
fever
18
metal
14
fever polymer
12
fume fever"
12
fever typically
12
polymer
10

Similar Publications

A 52-year-old male welder, who had been exposed to metal fumes and nitric acid without adequate protective measures, presented with symptoms of cough, dyspnea, and fever. He was admitted to our hospital, where bronchoscopy revealed hemorrhagic bronchoalveolar lavage fluid. He was diagnosed with diffuse alveolar hemorrhage (DAH) due to occupational inhalation of metal fumes and nitric acid.

View Article and Find Full Text PDF

[History and possible pathomechanisms of metal fume fever].

Orv Hetil

May 2024

3 Állatorvostudományi Egyetem, Gyógyszertani és Méregtani Tanszék Budapest Magyarország.

View Article and Find Full Text PDF

Febrile conditions often have an infectious etiology. However, there are also fevers associated with occupational exposures. A detailed occupational history can hold the key to the diagnosis.

View Article and Find Full Text PDF

Every structure might be exposed to fire at some point in its lifecycle. The ability of geopolymer composites to withstand the effects of fire damage early before it is put out is of great importance. This study examined the effects of fire on geopolymer composite samples made with high-calcium fly ash and alkaline solution synthesised from waste banana peduncle and silica fume.

View Article and Find Full Text PDF
Article Synopsis
  • Metal fume fever (MFF) is a work-related condition caused by inhaling metal particles like zinc oxide, with welders and metal workers being at high risk for chronic asthma as a long-term effect.
  • The study investigated the effects of zinc oxide (ZnO) fume inhalation on inflammation-related genes in mice, revealing significant increases in IL-17f and other cytokine expressions after exposure.
  • These findings suggest that IL-17f is key in linking immune responses and oxidative stress, which could help explain the development of allergic asthma among those exposed to ZnO fumes in metalworking jobs.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!