*Postgraduate Student, Department of Orthodontics, Juiz de Fora Federal University, Juiz de Fora, Brazil. †Professor, Department of Orthodontics, Juiz de Fora Federal University, Juiz de Fora, Brazil. ‡Professor, Department of Statistics, Juiz de Fora Federal University, Juiz de Fora, Brazil. §Associate Professor and Chair, Department of Orthodontics, Juiz de Fora Federal University, Juiz de Fora, Brazil.

Published: April 2015

Purpose: To determine the effect of field of view (FOV) size on gray values in cone beam computed tomography (CBCT) and multislice computed tomography (MSCT) images.

Material And Methods: A phantom made up of 3 cylinders containing distilled water, plaster, and motor oil was constructed and inserted into an acrylic cylinder filled with distilled water. The phantom was scanned with a CBCT and MSCT device using 3 FOV sizes. Gray value of each material was evaluated in 40 axial slices, and the comparison between the results obtained with the same FOV size was made.

Results: In CBCT examinations, there was significant difference between the gray values of different FOVs for the 3 materials. In the MSCT, there was significant difference for the oil. Gray values showed significant difference between the CBCT and MSCT examinations for the 3 materials in the 3 different FOV sizes.

Conclusions: Gray values determined in CBCT images are significantly influenced by the FOV size. Although the gray values obtained in MSCT have shown statistically significant differences between some acquisitions, the analysis of those differences seems to indicate low clinical relevance.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ID.0000000000000179DOI Listing

Publication Analysis

Top Keywords

gray values
24
fov size
16
cbct msct
12
size gray
8
computed tomography
8
distilled water
8
gray
7
cbct
6
msct
6
fov
6

Similar Publications

Aging has a significant impact on brain structure, demonstrated by numerous MRI studies using diffusion tensor imaging (DTI). While these studies reveal changes in fractional anisotropy (FA) across different brain regions, they tend to focus on white matter tracts and cognitive regions, often overlooking gray matter and motor areas. Additionally, traditional DTI metrics can be affected by partial volume effects.

View Article and Find Full Text PDF

Background/objectives: Sleep disturbances are prevalent among pediatric cancer survivors (PCSs) and their caregivers, often leading to poorer dietary choices and reduced physical activity. Additionally, the sleep quality and health behaviors of parents and children can affect each other. This study examined bi-directional associations between PCSs and their parents' sleep quality and health-related behaviors.

View Article and Find Full Text PDF

Research on Fire Detection of Cotton Picker Based on Improved Algorithm.

Sensors (Basel)

January 2025

College of Mechanical and Electrical Engineering, Xinjiang Agricultural University, Urumqi 830052, China.

According to the physical characteristics of cotton and the work characteristics of cotton pickers in the field, during the picking process, there is a risk of cotton combustion. The cotton picker working environment is complex, cotton ignition can be hidden, and fire is difficult to detect. Therefore, in this study, we designed an improved algorithm for multi-sensor data fusion; built a cotton picker fire detection system by using infrared temperature sensors, CO sensors, and the upper computer; and proposed a BP neural network model based on improved mutation operator hybrid gray wolf optimizer and particle swarm optimization (MGWO-PSO) algorithm based on the BP neural network model.

View Article and Find Full Text PDF

Diagnostic Cut-Off Values Based on Lipid Layer Pattern for Dry Eye Disease Subtypes Assessment.

J Clin Med

January 2025

GI-2092-Optometry, Departamento de Física Aplicada (Área de Optometría), Universidade de Santiago de Compostela, Campus Vida s/n, 15701 Santiago de Compostela, Spain.

: The aim of the present study was to establish a cut-off value of the Lipid Layer Pattern (LLP) between participants with different subtypes of Dry Eye Disease (DED) including Deficient Dry Eye (ADDE), Evaporative Dry Eye (EDE), and Mixed Dry Eye (MDE). : 240 participants diagnosed with DED according to the Tear Film and Ocular Surface Society in the Dry Eye Workshop II guidelines were included in the study. Tear Meniscus Height (TMH) using the Tearscope illumination and Meibomian Gland Loss Area (MGLA) using the Keratograph 5M were assessed to categorize the participants into an ADDE group, EDE group, or MDE group.

View Article and Find Full Text PDF

When using a fiber optic gyroscope as the core measurement element in an inertial navigation system, its work stability and reliability directly affect the accuracy of the navigation system. The modeling and fault diagnosis of the gyroscope is of great significance in ensuring the high accuracy and long endurance of the inertial system. Traditional diagnostic models often encounter challenges in terms of reliability and accuracy, for example, difficulties in feature extraction, high computational cost, and long training time.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!