This study investigates a tribological performance of diamond like carbon (DLC) coated micro dimpled prosthesis heads against ceramic cups in a novel pendulum hip joint simulator. The simulator enables determining friction coefficient and viscous effects of a concave shaped specimen interface (conformal contact). Two types of DLC such as hydrogenated amorphous carbon (a-C:H) and tetrahedral amorphous carbon (Ta-C) and one set of micro dimple (diameter of 300µm, depth of 70µm, and pitch of 900µm) were fabricated on metallic prosthesis heads. The experiment results reveal a significant friction coefficient reduction to the 'dimpled a-C:H/ceramic' prosthesis compared to a 'Metal (CoCr)/ceramic' prosthesis because of their improved material and surface properties and viscous effect. The post-experiment surface analysis displays that the dimpled a-C:H yielded a minor change in the surface roughness, and generated a larger sizes of wear debris (40-200nm sized, equivalent diameter), a size which could be certainly stored in the dimple, thus likely to reducing their possible third body abrasive wear rate. Thus, dimpled a:C-H can be used as a 'metal on ceramic hip joint interface', whereas the simulator can be utilized as an advanced bio-tribometer.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jmbbm.2014.11.028 | DOI Listing |
BMC Musculoskelet Disord
January 2025
Department of Orthopedics, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, 100045, China.
Background: Displaced tibial tubercle (TT) fractures in adolescents are typically treated with open reduction and internal fixation. While metallic screw (MS) fixation provides strong stability, it often results in a high incidence of postoperative screw head protrusion or irritation, leading to additional removal surgery. Bioabsorbable screw (BS) fixation presents an alternative that may avoid these issues, though its stability has not yet been extensively documented in the literature.
View Article and Find Full Text PDFJ Prosthet Dent
January 2025
Head and Neck Surgeon and Head, Verwelius 3D Lab, Department of Head and Neck Oncology and Surgery, Netherlands Cancer Institute, Amsterdam, The Netherlands.
Statement Of Problem: A nasal prosthesis may compensate for a partial or complete defect of the nose associated with trauma or amputation. However, the design and production is time-consuming, expensive, and expertize-dependent. Computer-generated prosthesis models and 3D printing can optimize the process.
View Article and Find Full Text PDFOtol Neurotol
February 2025
Department of Otorhinolaryngology-Head and Neck Surgery, Donders Center for Neuroscience, Radboud University Medical Center, Radboud University, Nijmegen, the Netherlands.
Objective: To compare the 3-year outcomes of the modified minimally invasive Ponto surgery (m-MIPS) to both the original MIPS (o-MIPS) and linear incision technique with soft tissue preservation (LIT-TP) for inserting bone-anchored hearing implants (BAHIs).
Study Design: Prospective study with three patient groups: m-MIPS, o-MIPS, and LIT-TP.
Setting: Tertiary referral center.
Otol Neurotol
February 2025
Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic, Rochester, Minnesota.
Objective: To analyze the use of electrical field imaging (EFI) in the detection of extracochlear electrodes in cochlear implants (CI).
Study Design: Retrospective cohort study.
Setting: Tertiary academic medical center.
Objective: The aim of this study is to test the feasibility of a custom 3D-printed guide for performing a minimally invasive cochleostomy for cochlear implantation.
Study Design: Prospective performance study.
Setting: Secondary care.