The P2X receptors are seven-transmembrane domain G protein-coupled receptors and the 7 subtypes of P2X receptors identified in humans, and named P2X1 to P2X7, are channel receptors whose endogenous ligand is ATP. New antagonists of the P2X7 receptor were developed, since this purinergic receptor was highlighted to be involved in many diseases such as different types of pain, cancer, ischemia, neurodegenerative diseases (including Parkinson's and Alzheimer's diseases) characterized by inflammatory processes. With the aim of evaluate the impact of chirality on the pharmacological activity of a new P2X7R antagonist, a semi-preparative method was developed in supercritical fluid chromatography (SFC). Among four polysaccharide based chiral stationary phases: Chiralcel OD-H and OJ-H and Chiralpak AS-H and AD-H, the last one namely amylose tris (3,5-dimethylphenylcarbamate) with a mobile phase consisted of carbon dioxide-ethanol (80:20, v/v), led to the successful separation of the enantiomers in short run time and with good resolution. Limits of detection and quantification were calculated and were found equal for compound 1, to 1.37 μM and 4.57 μM respectively, for peak 1 and were equal to 1.60 μM and 5.30 μM respectively, for peak 2 at λ=210 nm. Before carrying out the pharmacological evaluation of each enantiomer, two complementary methodologies, e.g. liquid chromatography and capillary electrophoresis were performed in parallel to improve the limits of detection and quantification to assess the enantiomeric purity. HPLC using a Chiralpak AD stationary phase led to four times lower limits of detection and quantification with regard to SFC. In the same time, capillary electrophoresis involving dual cyclodextrins system constituted of a SBE-β-CD and a MM-β-CD mixture enhanced the signal-to-noise ratio and led to similar limits of detection and quantification with regard to SFC. No trace of the other enantiomer was found in the isolated one. Biological activities of individual enantiomers were then evaluated and revealed no cytotoxicity against cell lines and a significant difference in terms of their IC50 values with respect to the investigated racemate (6.43 μM): 3.49 μM for the (R)-enantiomer and >10(-4)μM for the (S)-enantiomer, for compound 1, showing that, this antagonist activity is stereospecific.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2015.02.001DOI Listing

Publication Analysis

Top Keywords

limits detection
16
detection quantification
16
p2x receptors
8
μm peak
8
capillary electrophoresis
8
quantification regard
8
regard sfc
8
μm
6
evaluation comparison
4
comparison three
4

Similar Publications

Introduction: Non-Celiac Gluten Sensitivity (NCGS) is a common disorder characterized by symptoms resembling those of irritable bowel syndrome. In recent years there has been progress in the understanding of the pathogenic pathways and data suggest that NCGS has a distinct immunological profile that differs from celiac disease (CeD). This has fostered the search for a specific biomarker of NCGS.

View Article and Find Full Text PDF

In the present study, dispersive solid phase extraction - hydride generation integrated with micro-sampling gas-liquid separator - flame atomic absorption spectrometry was proposed to determine lead in lake water samples taken in the Horseshoe Island, Antarctica. In scope of this study, microwave assisted NiFeO nanoparticles were synthesized, and the characterization of nanoparticles were carried out by FT-IR, XRD and SEM. All influential parameters of dispersive solid phase extraction and hydride generation were optimized to enhance signal intensity belonging to the analyte.

View Article and Find Full Text PDF

A label-free, flexible, and disposable aptasensor was designed for the rapid on-site detection of vancomycin (VAN) levels. The electrochemical sensor was based on lab-printed carbon electrodes (C-PE) enriched with cauliflower-shaped gold nanostructures (AuNSs), on which VAN-specific aptamers were immobilized as biorecognition elements and short-chain thiols as blocking agents. The AuNSs, characterized by scanning electron microscopy (SEM) and atomic force microscopy (AFM), enhanced the electrochemical properties of the platform and the aptamer immobilization active sites.

View Article and Find Full Text PDF

This study introduces a novel ensemble learning technique namely Multi-Armed Bandit Ensemble (MAB-Ensemble), designed for lane detection in road images intended for autonomous vehicles. The foundation of the proposed MAB-Ensemble technique is inspired in terms of Multi-Armed bandit optimization to facilitate efficient model selection for lane segmentation. The benchmarking dataset namely TuSimple is used for training, validating and testing the proposed and existing lane detection techniques.

View Article and Find Full Text PDF

This study aimed to explore the diagnostic value of the two cytology techniques, including liquid-based cytology of mammary ductal lavage fluid and nipple discharge smear cytology, in the intraductal lesions in patients with pathological nipple discharge (PND). This retrospective analysis included 119 patients with PND who underwent surgical treatment. At the same time, they all underwent fiberoptic ductoscopy (FDS), nipple discharge smear cytology and liquid-based cytology of ductal lavage fluid before surgery.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!