The study aimed to assess the diagnostic value of high-resolution ultrasonography (HR-US) in the detection of anterior disc displacement (ADD) of the temporomandibular joint. Relevant trials reported in MEDLINE, the Chinese National Knowledge Infrastructure Database, the Chinese Biomedical Literature Database, and Embase were identified. A manual search was also performed. The quality of retrieved data was evaluated using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) criteria. Data were extracted and cross-checked, and a statistically rigorous meta-analysis was performed using a hierarchical summary receiver operating characteristic model (HSROC). The clinical utility of results was assessed using Fagan nomograms (Bayes theory). All data were evaluated using Stata software. A total 11 studies including 1096 subjects were included in the analysis; all reported the utility of HR-US for the diagnosis of ADD with reduction (ADDWR) and without reduction (ADDWoR). For ADDWR, the weighted sensitivity and specificity were 0.83 (95% confidence interval (CI) 0.78-0.88) and 0.85 (95% CI 0.76-0.92) respectively. The lambda value was 3.41 (95% CI 2.37-4.46) and the Fagan nomogram pre-test probability 58%, with a positive likelihood ratio (LR) of 6.01. The positive post-test probability was 89%, with a negative LR of 0.20. The negative post-test probability was 21%. The positive increase in diagnostic utility was 31% and the negative decrement in that value 37%. For ADDWoR, the weighted sensitivity and specificity values were 0.72 (95% CI 0.59-0.81) and 0.90 (95% CI 0.86-0.93), respectively. The lambda value was 3.69 (95% CI 2.39-4.99) and the Fagan nomogram pre-test probability 38%, with a positive LR of 7.00. The positive post-test probability was 82%, with a negative LR of 0.32. The negative post-test probability was 16%. The increase in diagnostic utility was 44% and the negative decrement in that value 22%. HR-US delivers acceptable performance when used to diagnose ADD, being superior for the detection of ADDWoR than ADDWR, and exhibiting a lower negative diagnostic value in the detection of ADDWoR than ADDWR. HR-US may serve as a new method for the rapid diagnosis of ADD. The method has the advantages of simplicity and low cost. Given the uncertainty in some of the estimated values, more high-quality studies are needed to assess that diagnostic efficacy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijom.2015.01.012DOI Listing

Publication Analysis

Top Keywords

post-test probability
16
addwor addwr
12
diagnostic high-resolution
8
high-resolution ultrasonography
8
detection anterior
8
anterior disc
8
disc displacement
8
temporomandibular joint
8
assess diagnostic
8
data evaluated
8

Similar Publications

Background: The features of community-acquired pneumonia (CAP) patients with type 2 diabetes mellitus (T2DM) differ from those without. This study aims to spot a routinely tested parameter with discriminative, predictive and prognostic value to enhance CURB-65's prognostic accuracy in CAP patients with T2DM.

Methods: We retrospectively studied consecutive CAP patients from 2020 to 2021, comparing laboratory parameters between patients with and without T2DM.

View Article and Find Full Text PDF

The utility of incorporating a usual interstitial pneumonia (UIP) genomic classifier (GC) and bronchoalveolar lavage (BAL) cell count analysis alongside traditional clinical-imaging assessment in aiding in the multidisciplinary diagnosis of IPF in patients with a non-definite HRCT UIP pattern is uncertain.We reviewed consecutive adult patients presenting with fibrotic interstitial lung disease (fILD) and non-definite HRCT UIP pattern who underwent BAL and GC. The initial fILD diagnoses were re-evaluated after bronchoscopy and a final multidisciplinary consensus diagnosis was provided.

View Article and Find Full Text PDF

High detection rate of parasitic load by qPCR targeting 18S rDNA in blood of patients with active leishmaniasis lesions.

Eur J Clin Microbiol Infect Dis

January 2025

Faculdade de Medicina, Laboratório de Parasitologia, Instituto de Medicina Tropical, Universidade de São Paulo, São Paulo, Brazil.

This study aimed to standardize qPCR techniques using these molecular markers kDNA and 18S rDNA across three sample types: peripheral blood, guanidine-treated blood, and tissue. The secondary objective is to evaluate the performance of 18S rDNA target in samples from 46 patients with confirmed tegumentary leishmaniasis. After obtaining the standard curve from reference strains with Leishmania, qPCR curves were standardizations and the Cts results of the patient samples were described using abstract measures.

View Article and Find Full Text PDF

Background: Pulse pressure variation (PPV) is limited in low tidal volume mechanical ventilation. We conducted this systematic review and meta-analysis to evaluate whether passive leg raising (PLR)-induced changes in PPV can reliably predict preload/fluid responsiveness in mechanically ventilated patients with low tidal volume in the intensive care unit.

Methods: PubMed, Embase, and Cochrane databases were screened for diagnostic research relevant to the predictability of PPV change after PLR in low-tidal volume mechanically ventilated patients.

View Article and Find Full Text PDF

: The HALP (Haemoglobin, Albumin, Lymphocyte and Platelet) score is used to predict the prognosis of different types of cancer. This study aimed to investigate the role of the HALP score in predicting pathological response in early-stage gastric cancer patients. : This retrospective cohort study was conducted on 118 patients diagnosed with early-stage gastric cancer and subjected to perioperative (FLOT) treatment between 2018 and 2023.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!