A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Visual evoked potentials and pulse wave velocity in inflammatory bowel disease. | LitMetric

Background/aims: Data about the effects of inflammatory bowel disease (IBD) on various functions of the nervous and cardiovascular systems are limited. In this study, the visual neuronal and cardiovascular functions of patients with IBD were evaluated by measuring visual evoked potentials (VEP) and pulse wave velocity (PWV), respectively.

Materials And Methods: There were three study groups: the Crohn's disease (CD) group (n=25), the ulcerative colitis (UC) group (n=30), and a healthy control (C) group (n=25). The exclusion criteria were as follows: patients with IBD were in remission, had no extra-intestinal manifestations of the disease, had no additional chronic disease(s), and had been receiving medical treatment for their IBD without any previous surgical intervention. VEP amplitudes (mV) and the N2 and P2 latencies (ms) were recorded for visual-neuronal analysis of all study groups. For cardiovascular assessment in all study groups, PWV was measured noninvasively as follows: the carotid-femoral PWV with the Complior Colson device (The authors have no conflict of interest.) and the PWV along the aorta with two ultrasound strain-gauge pressure-sensitive transducers (TY-306 Fukuda pressure-sensitive transducers - Fukuda Denshi Co, Tokyo, Japan) fixed transcutaneously over the course of a pair of arteries separated by a known distance. The right femoral and right common carotid arteries were the ones used.

Results: The PWV levels of the CD and UC groups were significantly higher than those in the C group (p<0.001). In the bilateral recording of the VEP, the N2 latencies of the CD (p<0.05) and UC (p<0.01) groups were significantly longer than those in the C group.

Conclusion: In this study, we showed vascular and visual neuronal impairments at a subclinical stage in patients with both types of IBD.

Download full-text PDF

Source
http://dx.doi.org/10.5152/tjg.2015.4349DOI Listing

Publication Analysis

Top Keywords

study groups
12
visual evoked
8
evoked potentials
8
pulse wave
8
wave velocity
8
inflammatory bowel
8
bowel disease
8
patients ibd
8
group n=25
8
pressure-sensitive transducers
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!