A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of a simple kit-based method for preparation of pharmaceutical-grade ⁶⁸Ga-DOTATOC. | LitMetric

Development of a simple kit-based method for preparation of pharmaceutical-grade ⁶⁸Ga-DOTATOC.

Nucl Med Commun

Nuclear Medicine Unit, Oncology and Advanced Technologies Department, IRCCS-Arcispedale Santa Maria Nuova, Reggio Emilia, Italy.

Published: May 2015

Introduction: The use of germanium-68 (⁶⁸Ge)/gallium-68 (⁶⁸Ga) generators is still limited when compared with the ⁹⁹Mo/⁹⁹mTc counterpart, mainly because of the absence of commercial kits and a kit-based method for preparing Ga-labelled radiopharmaceuticals in a reliable way. The present study aimed to develop and optimize a reliable direct labelling of DOTATOC with ⁶⁸Ga through a kit-based approach.

Materials And Methods: A fraction of the eluate of two different ⁶⁸Ge/⁶⁸Ga generators was directly injected into a vial prefilled with precursor, buffer and scavenger (the prototype of a potential lyophilized kit). The vial was directly warmed to 100°C and then buffered with a 1.5 mol/l sodium ascorbate solution. The parameters influencing the reaction were studied and optimized. The efficacy of the method in terms of incorporation yield and quality of the final radiotracer was compared with preparations performed with two commercial automatic synthesizers by applying the tests prescribed in the European Pharmacopeia monograph for ⁶⁸Ga-DOTATOC.

Results: Under optimal conditions, the overall radiochemical yields of the kit-based process were 73±4 and 69±3% not decay-corrected for the IGG100 and itG generator, respectively. The radiochemical purity was 95±3% and the preparations were compliant with all specifications given in the pharmacopoeia monograph.

Conclusion: The feasibility of a kit-based approach for the preparation of ⁶⁸Ga-DOTATOC was proved and a first home-made version of a putative lyophilized kit was proposed.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MNM.0000000000000275DOI Listing

Publication Analysis

Top Keywords

kit-based method
8
lyophilized kit
8
kit-based
5
development simple
4
simple kit-based
4
method preparation
4
preparation pharmaceutical-grade
4
pharmaceutical-grade ⁶⁸ga-dotatoc
4
⁶⁸ga-dotatoc introduction
4
introduction germanium-68
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!