Introduction: Diabetic retinopathy remains the leading visual complication of diabetes mellitus type 2 (DM2) in productive patients. It evolves from a non-proliferative stage, occasionally asymptomatic, until a proliferative phase with neovascularization, retinal detachment and blindness. There are many reports that compare visual, biochemical or electrophysiological parameters among diabetic patients and healthy controls. However, much less information has been published comparing parameters between diabetics with and without non-proliferative retinopathy. Thus, it is essential to know what changes take place in the retina and the visual post retinal pathway as the disease progresses, but before the establishment of a proliferative process involving blindness. Therefore, the purpose of this study was to compare and correlate electrophysiological and visual parameters of diabetics with and without non-proliferative retinopathy, using modern, non invasive techniques. These data will allow us to a better understanding of the process and to determine the use of these parameters in the monitoring of diabetes and its complications.
Material And Methods: This is an observational, prospective, transversal and analytical study. Twenty-two patients with DM2 were divided into two groups (50% on each group): group with non-proliferative retinopathy and group without retinopathy. We measured the central fovea thickness (CFT) by optical coherence tomography, the P100 wave of the Visual Evoked Potentials (VEP) and other visual and biochemical parameters.
Results: Retinopathy patients had lower visual acuity (p < 0.047), lower P100 amplitude (p < 0.043) and lower rate of rise (p < 0.026, 1-tailed). They also showed a more biochemical disturbance with higher glycemia (p < 0.015) and HbA1c (p < 0.033), and longer disease duration (p < 0.011), compared with those without retinopathy. Visual acuity showed a negative correlation with disease duration (r = -0.65; p < 0.017) and severity of ocular damage (r = -0.76; p < 0.007) in patients with retinopathy.
Conclusions: Patients with retinopathy have lower visual acuity, decreased central visual fibers and a tendency to increase the ECF. Although the data favor the use of these non-invasive techniques to monitor the disease and prevent progression of visual complications, additional studies are needed with larger sample size to confirm the results obtained here.
Download full-text PDF |
Source |
---|
Food Chem
December 2024
Laboratory of Functional Polymers, School of Materials Science and Engineering, Linyi University, Linyi 276005, China. Electronic address:
Organicphosphorus is a ubiquitous pesticide that has potential hazards to human health and environmental well-being. Therefore, the precise identification of residues of organophosphorus pesticides (OPs) emerges as an urgent necessity. A ratiometric fluorescent sensor for the detection of OPs by leveraging the catalytic activities of Ce and Ce on the two fluorescent substrates 4-Methylumbelliferyl phosphate (4-MUP) and o-phenylenediamine (OPD) correspondingly was designed.
View Article and Find Full Text PDFFood Chem
December 2024
Research Faculty and Graduate School of Agriculture, Hokkaido University, Sapporo, 060-8589, Japan. Electronic address:
To clarify the cause of graded distribution of sucrose in apple fruit flesh, a quarter cut of young apple fruit was cultured for 72 h on agar-solidified MS medium supplemented with 0.5 M [1-C]sorbitol, with the longitudinal or horizontal cut face being attached with the medium, and distribution of C-labelled sucrose in a specimen obtained by slicing the fruit along with the cut face was visualized utilizing MALDI-TOF MSI. Heat map images on the distribution of the peaks of sorbitol containing C-atom indicated that external [1-C]sorbitol had penetrated evenly into the tissue.
View Article and Find Full Text PDFFood Chem
December 2024
Department of Nutrition and Food Hygiene, School of Public Health, Tianjin Medical University, 300070 Tianjin, People's Republic of China; Tianjin Key Laboratory of Environment, Nutrition and Public Health, Center for International Collaborative Research on Environment, Nutrition and Public Health, Tianjin Medical University, Tianjin, People's Republic of China. Electronic address:
A novel biomimetic molecular imprinted polymer chip with fluorescence (FL) and structural (STR) states, inspired by color patterns of chameleon skin, is fabricated for detecting diethylstilbestrol (DES). The chip features a regularly structured, non-closed-packed (NCP) colloidal photonic crystal (CPC) lattice made monodisperse MIP spheres containing fluorescence poly ionic liquid (FPIL) pigments. The FL color originates from FPIL pigments and is further enhanced by the Purcell effect, while the STR color results from the periodic arrangement of the NCP CPC structure.
View Article and Find Full Text PDFJ Clin Neurophysiol
December 2024
Department of Neurology, Wake Forest University School of Medicine, Winston-Salem, North Carolina, U.S.A.
Purpose: High-frequency ultrasound (HFUS) of muscle and nerve has the potential to be a reliable, responsive, and informative biomarker of disease progression for individuals with amyotrophic lateral sclerosis (ALS). High-frequency ultrasound is not able to visualize median nerve fascicles to the same extent as ultra-high-frequency ultrasound (UHFUS). Evaluating the number and size of fascicles within a nerve may facilitate a better understanding of nerve diseases.
View Article and Find Full Text PDFInvest Radiol
October 2024
From the Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, University Zurich, Zurich, Switzerland (B.K., F.E., J.K., T.F., L.J.); Advanced Radiology Center, Department of Diagnostic Imaging and Oncological Radiotherapy, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Rome, Italy (C.S., A.R.L.); and Section of Radiology, Department of Radiological and Hematological Sciences, Università Cattolica del Sacro Cuore, Rome, Italy (A.R.L.).
Objectives: The aim of this study was to evaluate the feasibility and efficacy of visual scoring, low-attenuation volume (LAV), and deep learning methods for estimating emphysema extent in x-ray dose photon-counting detector computed tomography (PCD-CT), aiming to explore future dose reduction potentials.
Methods: One hundred one prospectively enrolled patients underwent noncontrast low- and chest x-ray dose CT scans in the same study using PCD-CT. Overall image quality, sharpness, and noise, as well as visual emphysema pattern (no, trace, mild, moderate, confluent, and advanced destructive emphysema; as defined by the Fleischner Society), were independently assessed by 2 experienced radiologists for low- and x-ray dose images, followed by an expert consensus read.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!