Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: The gold standard for paraproteinemia screening in plasma cell disorders has been serum protein electro- phoresis (SPE) with immunofixation electrophoresis (IFx); serum total and free light chain quantifications have also been used.
Objective: To define the role of SPE, IFx and serum total light chain (sLC) determinations in patients with multiple myeloma (MM), both at diagnosis and at maximum response during treatment follow-up.
Material And Methods: These serological studies were performed in a group of 62 patients with MM at diagnosis, and in a subset of 29 patients at the point of maximum response to treatment.
Results: At diagnosis, we found an abnormal SPE in 58%, an abnormal IFx in 92% and an abnormal sLC in 45% of the 62 patients; 64% had simultaneously abnormal results in all three serological studies. IFx alone proved to be the most sensitive of all three assays, followed by SPE, which was redundant in most instances with sLC and IFx. At maximum response, the abnormal SPE normalized in 7 cases, the abnormal IFx in 7 cases and the abnormal sLC in 7 cases. There were 12 instances in which an abnormal IFx was found despite normal sLC, and one case in which a normal IFx was found in the presence of abnormal sLC. The association between IFx and sLC was highly significant (r = 0.9274611, p < 0.000001), despite instances where a positive result for IFx was associated to a normal sLC.
Conclusion: All three serological methods should ideally be simultaneously performed in patients with MM both at diagnosis and throughout therapy. In this series, the total sLC assay was not more sensitive than IFx neither at diagnosis nor during follow-up.
Download full-text PDF |
Source |
---|
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!