A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Pedicle violation and Navigational errors in pedicle screw insertion using the intraoperative O-arm: A preliminary report. | LitMetric

Background: Use of computer-assisted insertion of pedicle screws has some advantages owing to the reportedly decreased incidence of pedicle breach and clinical events. Registration-based methods based on preoperative computed tomography imaging, 2D fluoroscopy, and 3D fluoroscopy are the most popular, however each has its limitations. O-arm-based navigation, which uses intraoperative acquisition and registration of navigated images, may overcome many of these disadvantages. We set out to study the clinical accuracy and navigational accuracy for pedicle screw insertion using our recently acquired O-arm and present our preliminary findings.

Methods: The first 26 patients operated consecutively for L4-5 fusion were included in the study. O-arm-based navigation was used to insert the pedicle screws. Postoperative computed tomography images were acquired and assessed for pedicle breach and anterior cortical perforation. Planned trajectories of each screw were compared with the actual trajectories in the postoperative images to assess navigational accuracy in both axial and sagittal planes.

Results: A total of 104 screws were inserted. One screw (1%) breached the pedicle laterally. Nonsignificant anterolateral cortical perforations were noted in 7 screws (6.7%), all of which occurred at L5 level. The mean axial and sagittal navigational error was 2.3° (±1.7) and 3.1° (±2.3), respectively. There were no significant differences in the errors between L4 or L5 level. The occurrence of anterior perforation correlated with the degree of axial (P = .02) but not sagittal (P = .12) navigational error. There were no clinical events related to the screw insertion.

Conclusion: Use of O-arm-guided pedicle screw insertion was associated with low incidence of pedicle breach (1%) and a low range of navigational error in both sagittal and axial planes. Anterolateral vertebral body perforation was higher at L5 without any negative clinical events. Despite the high need for technical support, we found that O-arm was a very efficient tool for accurate pedicle screw insertion.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4300978PMC
http://dx.doi.org/10.1016/j.ijsp.2013.06.002DOI Listing

Publication Analysis

Top Keywords

pedicle screw
16
screw insertion
16
pedicle breach
12
clinical events
12
axial sagittal
12
navigational error
12
pedicle
11
o-arm preliminary
8
pedicle screws
8
incidence pedicle
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!