A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Multicentre comparison Of shock efficacy using single-vs. Dual-coil lead systems and Anodal vs. cathodaL polarITY defibrillation in patients undergoing transvenous cardioverter-defibrillator implantation. The MODALITY study. | LitMetric

Purpose: An optimal active-can lead configuration during implantable cardioverter defibrillator (ICD) placement is important to obtain an adequate defibrillation safety margin. The purpose of this multicenter study was to evaluate the rate of the first shock success at defibrillation testing according to the type of lead implant (single vs. dual coil) and shock polarity (cathodal and anodal) in a large series of consecutive patients who received transvenous ICDs.

Methods: This was a multicenter study enrolling 469 consecutive patients. Single- versus dual-coil leads and cathodal versus anodal polarity were evaluated at defibrillation testing. In all cases, the value of the energy for the first shock was set to 20 J less than the maximum energy deliverable from the device.

Results: A total of 469 patients underwent defibrillation testing: 158 (34 %) had dual-coil and 311 (66 %) had single-coil lead systems configuration, 254 (54 %) received anodal shock and 215 (46 %) received cathodal shock. In 35 (7.4 %) patients, the shock was unsuccessful. No significant differences in the outcome of defibrillation testing using single- versus dual-coil lead were observed but the multivariate analysis showed an increased risk of shock failure using cathodal shock polarity (OR 2.37, 95 % CI 1.12-5.03).

Conclusions: Both single- and dual-coil transvenous ICD lead systems were associated with high rates of successful ICD implantation, and we found no significant differences in ventricular arrhythmias interruption between the two ICD lead systems configuration. Instead, anodal defibrillation was more likely to be successful than cathodal defibrillation.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10840-015-9980-9DOI Listing

Publication Analysis

Top Keywords

lead systems
16
defibrillation testing
16
shock
9
dual-coil lead
8
defibrillation
8
multicenter study
8
shock polarity
8
consecutive patients
8
single- versus
8
versus dual-coil
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!