A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of a noncontact heart rate monitoring system for sedentary behavior based on an accelerometer attached to a chair. | LitMetric

Although people spend a third of their day engaged in sedentary activities, research on heart activity during sitting is almost nonexistent because of the discomfort experienced when electrocardiogram (ECG) measurement electrodes are attached to the body. Accordingly, in this study, a system was developed to monitor heart rate (HR) in a noncontact and unconstrained way while subjects were seated, by attaching an accelerometer on the backrest of a chair. Acceleration signals were obtained three times from 20 healthy adults, a detection algorithm was applied, and HR detection performance was evaluated by comparing the R-peak values from the ECG. The system had excellent performance results, with a sensitivity of 96.10% and a positive predictive value of 96.43%. In addition, the HR calculated by the new system developed in this study was compared with HR calculated using ECG. The new system exhibited excellent performance; its results were strongly correlated with that of ECG (r = 0.97, p [Formula: see text] 0.0001; average difference of -0.08  ±  4.60 [mean ± 1.96∙standard deviation] in Bland-Altman analysis). Accordingly, the method presented in this study is expected to be applicable for evaluating diverse autonomic nervous system components in a noncontact and unconstrained way using an accelerometer to monitor the HR of sedentary workers or adolescents.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0967-3334/36/3/N61DOI Listing

Publication Analysis

Top Keywords

heart rate
8
system developed
8
noncontact unconstrained
8
ecg system
8
excellent performance
8
system
6
development noncontact
4
noncontact heart
4
rate monitoring
4
monitoring system
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!