Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Implantation of a medical implant within the body inevitably triggers a host inflammatory response that negatively impacts its function and longevity. Nevertheless, the degree and severity of this response may be reduced by selecting appropriate materials, implant geometry, surface topography and surface treatment. Here we demonstrate a strategy to improve the biocompatibility of a chemically-driven closed-loop insulin delivery implant. A microfabricated microporous, poly(ethylene glycol)-grafted polydimethylsiloxane membrane was placed on top of the glucose-responsive insulin release plug of the implant. Implant biocompatibility was assessed in healthy rats while implant function was evaluated in a type 1 diabetic rat model. The microporous membrane with a small distance to the plug provided a geometric barrier to inflammatory cell migration and prevented leukocyte-mediated degradation of the plug for at least 30 days. Membrane-protected devices elicited a significantly milder inflammatory response and formation of a well-defined fibrous capsule at the device opening compared to unprotected devices. The device's glucose-responsiveness was nearly unchanged, although the insulin release rate decreased with decreasing pore size. The microporous membrane improved biocompatibility and prolonged in vivo efficacy of the implant by ∼3-fold. This work suggests the importance of implant design in modulating inflammatory response and thereby extending the functional duration of the implant.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.biomaterials.2015.01.005 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!