Aim: To evaluate quantitative changes in anterior segment optical coherence tomography (AS-OCT) parameters at 4 years in subjects with open angles on gonioscopy at baseline.
Methods: 339 gonioscopically open-angle subjects aged >50 years underwent AS-OCT imaging (Visante, Carl Zeiss Meditec, Dublin, California, USA) at baseline and at 4 years. Customised software was used to analyse images. Linear regression was performed to assess baseline predictors of change in mean trabecular iris space area (TISA).
Results: Of the 339 subjects, 204 (61%) had good images for analysis. The mean age at baseline was 60 (SD 6.42) years; 55.4% were women and 87.7% were Chinese. Overall, there was a decrease in anterior chamber depth (ACD), anterior chamber area (ACA), anterior chamber volume (ACV) and angle opening distance at 500/750 µm, TISA 500/750 µm, iris thickness at 2000 µm and iris area in both nasal and temporal quadrants (p<0.05) at 4 years. There was an increase in iris curvature (ICURV) and lens vault (LV) (p<0.05). With univariate analysis, shorter axial length (AxL), shallower ACD, greater LV, smaller ACA/ACV and larger mean ICURV at baseline were associated with less change in TISA750 at follow-up. On multivariate analysis, only baseline mean ICURV and shorter AxL were predictive of less change in TISA750 at 4 years.
Conclusions: Angle width significantly decreased; ICURV and LV increased in subjects with gonioscopically open angles followed at 4 years. Eyes with shorter AxL and greater ICURV at baseline had lesser decrease in angle width.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1136/bjophthalmol-2014-305816 | DOI Listing |
J Glaucoma
January 2025
Department of Ophthalmology, Tan Tock Seng Hospital, National Healthcare Group Eye Institute, Singapore.
Purpose: Trabecular micro-bypass devices (TBDs) such as the iStent series (Glaukos Corporation, Laguna Hills, CA), are effective in reducing intraocular pressure (IOP). However, precise placement of TBDs is crucial in achieving surgical efficacy, as device malpositioning may lead to suboptimal IOP reduction. We demonstrate two novel intra-operative signs to aid confirmation of accurate iStent placement, without reliance on imaging technologies.
View Article and Find Full Text PDFSci Prog
January 2025
School of Medicine, University of Electronic Science and Technology of China, Chengdu, China.
Purpose: The aim of this study was to evaluate the efficacy and safety of the Ahmed glaucoma valve in pediatric patients with refractory glaucoma.
Methods: A comprehensive literature search was conducted across multiple major databases, including PubMed, Embase, the Cochrane Library of Systematic Reviews, Science Direct, China's National Knowledge Infrastructure, and the Wanfang database. We retrieved studies published before December 2022 that met the inclusion criteria, including clinical controlled trials (randomized controlled trials) and clinical noncontrolled trials (non-randomized controlled trials) on the use of Ahmed glaucoma valve in pediatric patients with refractory glaucoma.
Front Med (Lausanne)
January 2025
Shenzhen Eye Institute, Shenzhen Eye Hospital, Jinan University, Shenzhen, Guangdong, China.
Objective: This study aims to explore the differences in ocular parameters among adult myopic patients with different degrees of myopia and axial lengths, and to investigate the correlations between these ocular parameters.
Methods: This single-center observational study collected clinical data from myopic patients aged 18-45 years who visited the Eye Hospital of Nanjing Medical University between January and June 2023. The data included laterality, diopter of spherical power (DS), diopter of cylindrical power (DC), spherical equivalent (SE), axial length (AL), central corneal thickness (CCT), flat meridian keratometry (K1), steep meridian keratometry (K2), mean keratometry (Km), anterior chamber depth (ACD), corneal radius of curvature (CRC), and axial length/corneal radius of curvature ratio (AL/CRC).
Heliyon
January 2025
Ophthalmology Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy.
Purpose: To evaluate the intermediate-term visual and safety outcomes of the small-incision second-generation implantable miniature telescope (SING IMT) in patients with late-stage age-related macular degeneration (AMD) at 6 months post-surgery.
Design: Retrospective cohort study.
Methods: Medical records of patients implanted with the SING IMT at two sites in Italy were reviewed.
Heliyon
January 2025
Department of Psychiatry, National Clinical Research Center for Mental Disorders, and National Center for Mental Disorders, The Second Xiangya Hospital of Central South University, Changsha 410011, Hunan, China.
The anterior cingulate cortex is responsible for multiple cognitive functions like fear, pain management, decision-making, risk and reward assessment, and memory consolidation. However, its cell-type-specific functions are not clearly understood. To reveal the selective functional role of Parvalbumin-expressing GABAergic interneurons in the ACC, we knocked down (KD) the PV gene in-vivo in rats.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!