There is a paucity of information on the relationships between postoperative knee laxity and in vivo knee kinematics. The correlations were analyzed in 22 knees with axial radiographs and fluoroscopy based 3D model fitting approach after a tri-condylar total knee arthroplasty. During deep knee bend activities, the medial flexion gap had significant correlations with the medial contact point (r=0.529, P=0.011) and axial rotation at full extension. During kneeling activities, a greater medial flexion gap caused larger anterior translation at complete contact (r=0.568, P=0.011). Meanwhile, the lateral flexion gap had less effect. In conclusion, laxity of the medial collateral ligament should be avoided because the magnitude of medial flexion stability was crucial for postoperative knee kinematics.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2015.01.046DOI Listing

Publication Analysis

Top Keywords

flexion gap
16
knee kinematics
12
medial flexion
12
vivo knee
8
postoperative knee
8
knee
6
medial
5
analysis flexion
4
gap
4
gap vivo
4

Similar Publications

 To date, there are no uniform guidelines for the treatment of obstetric plexus lesions in German-speaking countries. An end-to-end direct suture after resection of trunk neuroma is recommended for surgical treatment if tension-free coaptation is possible, whereas the use of autologous nerve grafts bridging the gap between the adaptation margins is advised by consensus if tension-free coaptation is impossible.  The aim of the study was to investigate which reconstruction strategy may provide a better recovery of motor function for patients after obstetric brachial plexus lesion.

View Article and Find Full Text PDF

Purpose: Gap-balanced total knee arthroplasty (TKA) technique relies on initial ligament evaluation, particularly in patient-specific implantation using computer-assisted technologies. This cadaveric study aimed to compare the reproducibility and reliability of medial and lateral gap measurements between manual stress testing and dynamic ligament balancer.

Methods: Initial gap acquisitions were assessed from eight cadaveric knees (four specimens) during the same navigated TKA procedure by five differently skilled surgeons (three seniors and two juniors).

View Article and Find Full Text PDF

Functional alignment is a feasible alignment strategy in robotic assisted total knee arthroplasty for knee osteoarthritis with extra-articular deformity - A case series.

SICOT J

January 2025

Department of Orthopaedic Surgery, Joint Replacement Unit, Kuala Lumpur Hospital, Ministry of Health Malaysia, Jalan Pahang, 50586 Kuala Lumpur, Malaysia.

Introduction: Extraarticular deformity (EAD) with knee arthritis is a complex condition involving tri-planar bone deformity with pathological malalignment and chronic soft tissue contracture or laxity in the knee joint. Intraarticular correction by TKA, which was previously performed with conventional manual jig by mechanical alignment technique, had its limits and difficulties especially extensive soft tissue release and risk of jeopardizing the collateral ligaments. Robotic technology allows for reproducible and precise execution of surgical plan and allows adjustment to various new personalised alignment philosophy including functional alignment (FA).

View Article and Find Full Text PDF

Background: This study investigates the association between intra-operative balance and 2-year outcomes within subgroups defined by demographics and pre-operative joint balance. Our hypothesis is that patient demographics and the pre-operative state of the joint will impact patient sensitivity to post-operative balance and laxity and subsequent impact on outcome.

Methods: A retrospective analysis of prospectively captured data across 5 sites with 5 surgeons was performed.

View Article and Find Full Text PDF

Among control methods for robotic exoskeletons, biologically inspired control based on central pattern generators (CPGs) offer a promising approach to generate natural and robust walking patterns. Compared to other approaches, like model-based and machine learning-based control, the biologically inspired control provides robustness to perturbations, requires less computational power, and does not need system models or large learning datasets. While it has shown effectiveness, a comprehensive evaluation of its user experience is lacking.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!