Objective: The purpose of the study was to evaluate the safety and feasibility of treatment for male circumcision using modified sleeve circumcision and subcuticular suture with the Quill™ device.

Methods: From May 2011 to March 2012, 70 consecutive cases of male circumcision were performed using an alternative technique with the Quill™ device by a single surgeon in our institution. The inclusion and exclusion criteria for the selection process of this procedure were the same as for conventional circumcision. We evaluated the indications and perioperative outcomes. The circumcisions were performed as day-case procedures under local anesthesia.

Results: All patients were followed up for a minimum of 3-6 months. The ages ranged from 8 to 68 (mean = 27.0 years, SD = 10). The indications for surgery were either cosmetic (n = 16, 22.9%) or medical [redundant prepuce (n = 36, 51.4%), phimosis (n = 5, 7.1%), paraphimosis (n = 2, 2.9%), balanoposthitis (n = 9, 12.9%), melanoma (n = 1, 1.4%), and condyloma acuminata (n = 1, 1.4%)] (n = 54, 77.1%). The mean operation time in this group was 29 min (19-38 min) when the Quill™ device was used. In all, 3 cases developed complications (4.3%). The final cosmetic result was satisfactory for both the patients and their spouses or parents.

Conclusion: This study showed that modified sleeve circumcision and subcuticular suture were safe and reliable surgical methods of circumcision that provide a better cosmetic result.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000368660DOI Listing

Publication Analysis

Top Keywords

quill™ device
12
modified sleeve
12
sleeve circumcision
12
male circumcision
8
circumcision subcuticular
8
subcuticular suture
8
cosmetic result
8
circumcision
7
introducing quill™
4
device modified
4

Similar Publications

Surface Fluorination of Silicone Rubber with Enhanced Stain Resistance and Slip Properties.

ACS Appl Mater Interfaces

January 2025

State Key Laboratory of Polymer Materials Engineering, College of Polymer Science and Engineering, Sichuan University, Chengdu, Sichuan 610065, P.R. China.

Silicone rubber (SR) holds significant potential for everyday wearable devices due to its inherent sweat resistance and flexibility. However, its broader applicability is constrained by poor oil resistance and a suboptimal slip performance. In this study, we developed an SR with durable oil resistance and enhanced slip properties by forming a covalently bonded barrier layer on its surface through a one-step in situ fluorination reaction using F/N.

View Article and Find Full Text PDF

Introduction: Intensive research is dedicated to the development of novel biomaterials and medical devices to be used as grafts in reconstructive surgery, with the purpose of enhancing their therapeutic effectiveness, safety, and durability. A variety of biomaterials, from autologous bone to polymethylmetacrylate, polyether ether ketone, titanium, and calcium-based ceramics are used in cranioplasty. Porous hydroxyapatite (PHA) is reported as a possible material for bone reconstruction, with good signs of biocompatibility, osteoconductive and osteointegrative properties.

View Article and Find Full Text PDF

Background: Point-of-care ultrasound (POCUS) can be used in a variety of clinical settings and is a safe and powerful tool for ultrasound-trained healthcare providers, such as physicians and nurses; however, the effectiveness of ultrasound education for nursing students remains unclear. This prospective cohort study aimed to examine the sustained educational impact of bladder ultrasound simulation among nursing students.

Methods: To determine whether bladder POCUS simulation exercises sustainably improve the clinical proficiency regarding ultrasound examinations among nursing students, evaluations were conducted before and after the exercise and were compared with those after the 1-month follow-up exercise.

View Article and Find Full Text PDF

Background: Management of the extensive soft tissue injuries remains a significant challenge in orthopedic and plastic reconstructive surgery. Since the thumb is responsible for 40% of the functions of the hand, saving and reconstructing a mangled thumb is essential for the patient's future.

Case Presentation: This case report describes the management of a severe occupational thumb injury in a 25-year-old white Persian male who sustained an occupational injury to his left thumb, resulting in extensive burn, crush injury to the distal and proximal phalanx, and severe soft tissue damage to the first metacarpal, thenar, and palmar areas.

View Article and Find Full Text PDF

Background: Metabolic and bariatric surgery (MBS) is a suitable solution for the treatment of morbid obesity. Investigating an MBS method that has the best outcomes has always been the main concern of physicians. The current study aimed to compare nutritional, anthropometric, and psychological complications of individuals undergoing various MBS Techniques.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!