Complex dynamics of a dc glow discharge tube: Experimental modeling and stability diagrams.

Sci Rep

1] Istituto Nazionale di Ottica, Consiglio Nazionale delle Ricerche, Largo E. Fermi 6, 50125 Firenze, Italy [2] Departamento de Física, Universidade Federal da Paraíba, 58051-970 João Pessoa, Brazil [3] CELC, Departamento de Matemática, Faculdade de Ciências, Universidade de Lisboa 1749-016 Lisboa, Portugal [4] Instituto de Altos Estudos da Paraíba, Rua Infante Dom Henrique 100-1801, 58039-150 João Pessoa, Brazil [5] Max-Planck Institute for the Physics of Complex Systems, Nöthnitzer Str. 38, 01187 Dresden, Germany.

Published: February 2015

We report a detailed experimental study of the complex behavior of a dc low-pressure plasma discharge tube of the type commonly used in commercial illuminated signs, in a microfluidic chip recently proposed for visible analog computing, and other practical devices. Our experiments reveal a clear quasiperiodicity route to chaos, the two competing frequencies being the relaxation frequency and the plasma eigenfrequency. Based on an experimental volt-ampere characterization of the discharge, we propose a macroscopic model of the current flowing in the plasma. The model, governed by four autonomous ordinary differential equations, is used to compute stability diagrams for periodic oscillations of arbitrary period in the control parameter space of the discharge. Such diagrams show self-pulsations to emerge remarkably organized into intricate mosaics of stability phases with extended regions of multistability (overlap). Specific mosaics are predicted for the four dynamical variables of the discharge. Their experimental observation is an open challenge.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4326696PMC
http://dx.doi.org/10.1038/srep08447DOI Listing

Publication Analysis

Top Keywords

discharge tube
8
stability diagrams
8
discharge
5
complex dynamics
4
dynamics glow
4
glow discharge
4
experimental
4
tube experimental
4
experimental modeling
4
modeling stability
4

Similar Publications

Prolapsed fallopian tube to the vagina after hysterectomy a year ago: A case report.

Taiwan J Obstet Gynecol

January 2025

Department of Obstetrics and Gynecology, Chung Shan Medical University Hospital, Taichung 40203, Taiwan; Institute of Medicine, Chung Shan Medical University, Taichung 40203, Taiwan.

Objective: This case report aims to present a rare occurrence of fallopian tube prolapse into the vaginal vault following hysterectomy, underscoring the importance of recognizing this uncommon complication.

Case Report: A 45-year-old woman, with a history of hysterectomy for adenomyosis, presented with symptoms mimicking a vaginal tumor, including persistent discharge, abdominal pain, postcoital bleeding, and weight loss. Imaging raised concerns of malignancy, but surgery revealed a prolapsed fallopian tube with chronic inflammation.

View Article and Find Full Text PDF

Rationale: Enteral nutrition is a critical component of care for critically ill patients. However, the blind insertion of a nasoenteric tube, despite being a simple procedure, carries inherent risks that necessitate a reevaluation of the technique.

Patient Concerns: A case of a 60-year-old female experienced the rare yet critical complication of a misplaced nasoenteric tube entering the thoracic cavity during a blind insertion procedure for enteral nutrition following a liver transplant.

View Article and Find Full Text PDF

Background: The study evaluated the safety and adequacy of percutaneous transsternal anterior mediastinal core biopsy.

Methods: All percutaneous computed tomography-guided transsternal mediastinal 18-gauge core biopsies performed at 2 academic centers were retrospectively reviewed. Procedural, clinical, and pathology data were recorded.

View Article and Find Full Text PDF

Objective: Recent advancements in chest tube technologies have gained interest for their ability to enhance postoperative recovery via reduction of retained blood syndrome after cardiothoracic surgery. The present study investigates the effect of the Centese Thoraguard automated line-clearance chest tube system on postoperative pain and recovery after cardiac surgery.

Methods: This was a single-center retrospective review of 1771 adult patients undergoing nonemergency cardiac surgery between January 2021 and December 2022.

View Article and Find Full Text PDF

Though several studies have demonstrated that preoperative oral feeding (PO) can be safe in patients with congenital heart disease, they are commonly prohibited from doing so, potentially precluding the development of such skills. We sought to determine whether preoperative oral feeding is associated with freedom from tube feeding at postoperative discharge. Single-center, observational study including patients in the first month of life (≤ 30 days of age) who underwent a single cardiac surgery between 7/1/2017-6/30/2022 and survived to discharge.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!