Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Aim of the present study was to compare clinical outcome of intermittent cold (ICC) versus intermittent warm (IWC) blood cardioplegia in different cardiosurgical procedures.
Methods: Two thousand one hundred and eighty-eight patients were retrospectively divided into 5 groups: isolated coronary artery bypass surgery (CABG; N.=1203), isolated aortic valve surgery (AVR; N.=374), isolated mitral valve surgery (MVR; N.=151), combined AVR+CABG (N.=390), and combined MVR+CABG (N.=70). Myocardial protection was performed by ICC (N.=1578) or IWC (N.=610) blood cardioplegia. In logistic regression models the effect of cardioplegia on 30-day mortality, IABP/ECLS (intraaortic balloon-pump/extracorporal life support) implantation, transient neurological deficit, stroke, renal failure, new-onset atrial fibrillation, and troponin T release was estimated. Potential modifications of the effect of cardioplegia by logistic EuroSCORE, cross-clamping time, ejection fraction, and op-status elective versus urgent/emergent were investigated.
Results: There were no statistically significant differences between ICC and IWC regarding 30-day mortality (odds ratio [OR]=0.70; 95% CI: 0.39-1.23; P=0.219), IABP/ECLS support (OR=0.60; 95% CI: 0.23-1.55; P=0.294), transient neurological deficit (OR=0.90; 95% CI: 0.65-1.24; P=0.541), stroke (OR=0.79; 95% CI: 0.40-1.54; P=0.495), renal failure (OR=1.07; 95% CI: 0.57-1.99; P=0.825), and atrial fibrillation (OR=0.96; 95% CI: 0.77-1.18; P=0.713) across all 5 groups. Troponin t release was significantly higher in ICC compared to IWC (by 0.029±0.015 ng/mL; P=0.046) in univariate analysis; this effect was lowered by risk-factor adjustment and lost statistical significance. The effect of cardioplegia was not significantly different between groups. In urgent/emergent surgery ICC resulted in a significantly higher 30-day mortality (OR=3.03; P=0.024) compared to IWC.
Conclusions: The comparison of IWC and ICC blood cardioplegia in different cardiosurgical procedures showed no statistical significant difference in myocardial protection. The use of ICC, however, appeared overall associated with a slightly better clinical outcome except in patients undergoing urgent/emergent CABG where IWC led to a reduction in 30-day-mortality.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.23736/S0021-9509.16.08525-X | DOI Listing |