Comparison of blood ethanol stabilities in different storage periods.

Biochem Med (Zagreb)

Dumlupinar University, Evliya Celebi Education, and Research Hospital, Department of Medical Biochemistry, Kutahya, Turkey.

Published: March 2015

Introduction: Measurements of blood ethanol concentrations must be accurate and reliable. The most important factors affecting blood ethanol stability are temperature and storage time. In this study, we aimed to compare ethanol stability in plasma samples at -20 °C for the different storage periods.

Materials And Methods: Blood samples were collected from intoxicated drivers (N=80) and initial plasma ethanol concentrations were measured immediately. Plasma samples were then stored at -20 °C and re-assessed after 2, 3, 4, or 5 months of storage. Differences between the initial and stored ethanol concentrations in each group (N=20) were analyzed using Wilcoxon matched-pairs test. The deviation from the initial concentration was calculated and compared with Clinical Laboratory Improvement Amendments (CLIA'88) Proficiency Testing Limits. Relationships between the initial concentrations and deviations from initial concentrations were analyzed by Spearman's correlation analysis. For all statistical tests, differences with P values of less than 0.05 were considered statistically significant.

Results: Statistically significant differences were observed between the initial and poststorage ethanol concentrations in the overall sample group (P<0.001). However, for the individual storage duration groups, analytically significant decreases were observed only for samples stored for 5 months, deviations from the initial concentrations exceeded the allowable total error (TEa). Ethanol decreases in the other groups did not exceed the TEa.

Conclusion: According to our results, plasma ethanol samples can be kept at -20 °C for up to 3-4 months until re-analysis. However, each laboratory should also establish its own work-flow rules and criterion for reliable ethanol measurement in forensic cases.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4401314PMC
http://dx.doi.org/10.11613/BM.2015.006DOI Listing

Publication Analysis

Top Keywords

ethanol concentrations
16
blood ethanol
12
ethanol stability
8
plasma samples
8
-20 °c
8
initial concentrations
8
ethanol
7
concentrations
6
initial
6
comparison blood
4

Similar Publications

This study investigates the antioxidant, antimicrobial, and anticancer properties of Pancratium maritimum L. in Sp. Pl.

View Article and Find Full Text PDF

Background: Alcohol intake is associated with a higher risk of estrogen receptor-positive (ER+) breast cancer (BC), presumably through its confirmed ability to increase sex hormone levels. Whether consuming alcohol within the recommended limit of one serving per day increases sex hormone levels among postmenopausal women taking aromatase inhibitors (AI) to inhibit estrogen production remains unknown. Therefore, we compared sex hormone levels following white wine to levels following white grape juice among ER + BC survivors taking AIs.

View Article and Find Full Text PDF

Motor vehicle accidents (MVA) are the leading cause of death in childhood and young adult age. One of the most important factors behind MVA is driving under the influence of alcohol (DUIA) and drugs (DUID). The importance of DUID is rising together with the increasing drug abuse.

View Article and Find Full Text PDF

An in situ monitoring reaction can better obtain the variations during the progression of the photocatalytic reaction. However, the complexity of the apparatus and the limited applicability of substances are the common challenges faced by most in situ monitoring methods. Here, we invented an in situ infrared optical fiber sensor to monitor the reactants and products during photocatalytic reaction.

View Article and Find Full Text PDF

Removal of lithium from aqueous solutions by precipitation with sodium and choline alkanoate soaps.

Green Chem

December 2024

KU Leuven, Department of Chemistry Celestijnenlaan 200F P.O. box 2404 B-3001 Leuven Belgium

In order to comply with the expected tightening of discharge limits for lithium to surface waters, the lithium-ion battery industry will need access to methods to reduce the concentration of lithium in wastewater down to ppm levels. In this Communication, we discuss the possibility of using sodium and choline soaps as precipitating agents for lithium, comparing the two soap classes and probing the influence of the carbon chain length. It was found that lithium concentrations down to 10 ppm can be reached with sodium stearate, and down to 1 ppm with choline stearate, using a slight excess of the precipitating agent.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!