Drug-eluting stents (DES), delivering antiproliferative drugs from a durable polymer, have shown to reduce in-stent restenosis after percutaneous coronary intervention (PCI) compared to bare-metal stents (BMS). However, they have been associated with a hypersensitivity reaction, delayed healing, and incomplete endothelialization, which may contribute to an increased risk of late stent thrombosis. Consequently, a prolonged duration of dual antiplatelet therapy (DAPT) is needed, with an increased risk of bleeding complication. A number of stent technologies are being developed in an attempt to modify late thrombotic events and DAPT duration. The Optimax™ stent is such a novel, next generation bioactive stent (BAS), in which a thicker layer of titanium-nitride-oxide coating is inserted over the stent struts. The rationale of this is to obtain more efficient and rapid vascular healing at the site of the stent implantation. The aim of TIDES-ACS Trial is to compare clinical outcome in patients presenting with ACS, treated with PCI using Optimax-BAS versus Synergy™-EES. Second objective is to explore whether the Optimax™-BAS use is superior compared with Synergy™-EES use with respect of hard end points (cardiac death, myocardial infarction [MI] and major bleeding). A prospective, randomized, multicenter trial (ClinicalTrials.gov Identifier: NCT02049229), will be conducted in interventional centres in Finland (six centres), France (five centres) and Holland (two centres), including a total of 1800 patients.
Download full-text PDF |
Source |
---|
JAMA Cardiol
July 2023
Cardiovascular Center Aalst, OLV-Clinic, Aalst, Belgium.
Importance: Titanium-nitride-oxide (TiNO)-coated stents show faster strut coverage compared with drug-eluting stents without excessive intimal-hyperplasia observed in bare metal stents. It is important to study long-term clinical outcomes after treatment of patients with an acute coronary syndrome (ACS) by TiNO-coated stents, which are neither drug-eluting stents nor bare metal stents.
Objective: To compare the rate of main composite outcome of cardiac death, myocardial infarction (MI), or ischemia-driven target lesion revascularization at 5 years in patients with ACS randomized to receive either a TiNO-coated stent or a third-generation everolimus-eluting stent (EES).
JACC Cardiovasc Interv
July 2020
Heart Center, Satakunta Central Hospital, Pori, Finland; Heart and Lung Center, Helsinki University Hospital, Helsinki, Finland.
Objectives: This study sought to compare next-generation cobalt-chromium-based titanium-nitride-oxide (TiNO)-coated stents with a platinum-chromium-based biodegradable polymer everolimus-eluting stent (EES) in patients with acute coronary syndrome (ACS).
Background: Previous generation TiNO-coated stents showed acceptable performance in patients with ACS.
Methods: In a multicenter, randomized trial, we randomly assigned 1,491 ACS patients (2:1) to receive either a TiNO-coated stent (n = 989) or EES (n = 502).
Cardiovasc Revasc Med
August 2019
Hospital Clinico San Carlos, Dpt. of Interventional Cardiology, Madrid, Spain.
Objectives: We investigated the safety and efficacy of the bioabsorbable polymer-coated, everolimus-eluting coronary stent (SYNERGY) stent in a real-world study population with acute coronary syndromes (ACS).
Background: A number of clinical trials support the overall efficacy and safety of the SYNERGY stent. However, a recent trial (TIDES-ACS) in the context of ACS reported worrying figures of infarction and definite/probable stent thrombosis in the SYNERGY control arm.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!