Nanoscale bonding between human bone and titanium surfaces: osseohybridization.

Biomed Res Int

Advanced Analysis Center, Korea Institute of Science and Technology, 5 Hwarang-ro 14-gil, Seongbuk-gu, Seoul 136-791, Republic of Korea.

Published: November 2015

Until now, the chemical bonding between titanium and bone has been examined only through a few mechanical detachment tests. Therefore, in this study, a sandblasted and acid-etched titanium mini-implant was removed from a human patient after 2 months of placement in order to identify the chemical integration mechanism for nanoscale osseointegration of titanium implants. To prepare a transmission electron microscopy (TEM) specimen, the natural state was preserved as much as possible by cryofixation and scanning electron microscope/focused ion beam (SEM-FIB) milling without any chemical treatment. High-resolution TEM (HRTEM), energy dispersive X-ray spectroscopy (EDS), and scanning TEM (STEM)/electron energy loss spectroscopic analysis (EELS) were used to investigate the chemical composition and structure at the interface between the titanium and bone tissue. HRTEM and EDS data showed evidence of crystalline hydroxyapatite and intermixing of bone with the oxide layer of the implant. The STEM/EELS experiment provided particularly interesting results: carbon existed in polysaccharides, calcium and phosphorus existed as tricalcium phosphate (TCP), and titanium existed as oxidized titanium. In addition, the oxygen energy loss near edge structures (ELNESs) showed a possibility of the presence of CaTiO3. These STEM/EELS results can be explained by structures either with or without a chemical reaction layer. The possible existence of the osseohybridization area and the form of the carbon suggest that reconsideration of the standard definition of osseointegration is necessary.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4312565PMC
http://dx.doi.org/10.1155/2015/960410DOI Listing

Publication Analysis

Top Keywords

titanium bone
8
energy loss
8
titanium
7
chemical
5
nanoscale bonding
4
bonding human
4
bone
4
human bone
4
bone titanium
4
titanium surfaces
4

Similar Publications

Modern techniques of rib fracture fixation surgery follow the AO principles of fracture reduction, fixation, and appropriate soft tissue handling. Fixation techniques can be performed using anatomic reduction and rigid fixation, or bridge plate fixation for comminuted fractures. Anatomic and nonanatomic plates can be used, although titanium precontoured locking plates are the most commonly used.

View Article and Find Full Text PDF

Background/purpose: Titanium (Ti) is extensively used in dental and orthopedic implants due to its excellent mechanical properties. However, its smooth and biologically inert surface does not support the ingrowth of new bone, and Ti ions may have adverse biological effects. The purpose is to improve the corrosion resistance of titanium and create a 3D structured coating to enhance osseointegration through a very simple and fast surface treatment.

View Article and Find Full Text PDF

Osseointegration is a crucial property of biomaterials used for bone defect repair. While titanium is the gold standard in craniofacial surgeries, various polymeric biomaterials are being explored as alternatives. However, polymeric materials can be bioinert, hindering integration with surrounding tissues.

View Article and Find Full Text PDF

Dental titanium implants and their surface modifications markedly improve implant biocompatibility. However, studies evaluating the mechanical biocompatibility of implants are scarce. In particular, the analysis of mechanical biocompatibility deficiencies leading to stress shield-induced bone resorption.

View Article and Find Full Text PDF

Enhanced bone cement for fixation of prosthetic joint utilizing nanoparticles.

J Mater Sci Mater Med

January 2025

Biomedical Engineering Department, Faculty of Engineering, Helwan University, Cairo, Egypt.

Bone cement is commonly utilized to secure prosthetic joints in the body because of its robust fixation, stability, biocompatibility, and immediate load-bearing capability. However, issues such as loosening, leakage, and insufficient bioactivity can lead to its failure. Therefore, improving its mechanical, physical, and biological properties is crucial for enhancing its efficiency.

View Article and Find Full Text PDF