A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Optimization of electrically active magnetic nanoparticles as accurate and efficient microbial extraction tools. | LitMetric

Optimization of electrically active magnetic nanoparticles as accurate and efficient microbial extraction tools.

Biosensors (Basel)

Department of Biosystems and Agricultural Engineering, Michigan State University, 115 Farrall Hall, East Lansing, MI 48824, USA.

Published: February 2015

Food defense requires the means to efficiently screen large volumes of food for microbial pathogens. Even rapid detection methods often require lengthy enrichment steps, making them impractical for this application. There is a great need for rapid, sensitive, specific, and inexpensive methods for extracting and concentrating microbial pathogens from food. In this study, an immuno-magnetic separation (IMS) methodology was developed for Escherichia coli O157:H7, using electrically active magnetic nanoparticles (EAMNPs). The analytical specificity of the IMS method was evaluated against Escherichia coli O55:H7 and Shigella boydii, and was improved over previous protocols by the addition of sodium chloride during the conjugation of antibodies onto MNPs. The analytical sensitivity of the IMS method was greatest when a high concentration of antibodies (1.0 mg/mL) was present during conjugation. EAMNP concentrations of 1.0 and 0.5 mg/mL provided optimal analytical sensitivity and analytical specificity. The entire IMS procedure requires only 35 min, and antibody-conjugated MNPs show no decline in performance up to 149 days after conjugation. This analytically sensitive and specific extraction protocol has excellent longevity and shows promise as an effective extraction for multiple electrochemical biosensor applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4384083PMC
http://dx.doi.org/10.3390/bios5010069DOI Listing

Publication Analysis

Top Keywords

electrically active
8
active magnetic
8
magnetic nanoparticles
8
microbial pathogens
8
sensitive specific
8
escherichia coli
8
analytical specificity
8
ims method
8
analytical sensitivity
8
optimization electrically
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!