A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 144

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3106
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Extraction of superfluous device leads: A comparison with removal of infected leads. | LitMetric

Background: Although increasingly more lead extraction was performed for superfluous leads, the extraction of such leads remains controversial.

Objective: The objective of this study was to determine the outcomes and complications of transvenous extraction of superfluous leads in a single center in the era of laser technology.

Methods: Four hundred eighty transvenous lead extraction procedures performed from January 2001 through October 2012 at Mayo Clinic (Rochester, Minnesota) were retrospectively reviewed. Of these, 123 procedures were performed for superfluous functional or nonfunctional leads. Data were collected from electronic medical records and an institutional database of cardiovascular implantable electronic devices.

Results: A total of 167 superfluous leads (mean [SD] lead duration 53 [53] months; median 34 months) were removed during the 123 procedures. Forty-one percent of procedures were for lead malfunction. The procedural complete-success rate was 96.7%. Major complications occurred in 1 patient (0.8%), who had a superior vena cava tear that required thoracotomy. Superfluous leads had been implanted for a shorter period of time than infected leads (mean [SD] 53 [53] vs 81 [59] months; P < .001). The procedural complete-success rate was higher for the removal of superfluous leads than for leads associated with infection (97% vs 92%; P = .05).

Conclusion: Transvenous extraction of superfluous leads is highly successful, with few procedural complications. Extraction of superfluous leads at the time of device upgrade or lead revision is considered reasonable to avoid the increasing risk of extraction complications with lead aging.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hrthm.2015.02.005DOI Listing

Publication Analysis

Top Keywords

superfluous leads
28
extraction superfluous
16
leads
13
extraction
8
infected leads
8
lead extraction
8
superfluous
8
performed superfluous
8
transvenous extraction
8
procedures performed
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!