Transapical transcatheter aortic valve implantation can be complicated by subannular device embolization. We describe 2 cases of transapical extraction without conversion to sternotomy, with a discussion of contributing factors and our strategy for salvage.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cjca.2014.10.038DOI Listing

Publication Analysis

Top Keywords

transapical transcatheter
8
transcatheter aortic
8
aortic valve
8
valve implantation
8
subannular prosthetic
4
prosthetic valve
4
valve embolization
4
embolization complicating
4
complicating transapical
4
implantation management
4

Similar Publications

Background: There are few reports about the one-stage surgery of transcatheter aortic valve replacement (TAVR) + mitral valve transcatheter edge-to-edge repair (M-TEER) around the world. TAVR + M-TEER surgery is usually performed under the simultaneous guidance of digital subtraction angiography (DSA) and echocardiography. There is no report of TAVR surgery assisted only by echocardiography all over the world.

View Article and Find Full Text PDF

Outcomes of a transapical edge-to-edge repair system in secondary mitral regurgitation.

J Invasive Cardiol

January 2025

Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, China; State Key Laboratory of Cardiovascular Diseases, Zhongshan Hospital, Fudan University; NHC Key Laboratory of Ischemic Heart Diseases; Key Laboratory of Viral Heart Diseases, Chinese Academy of Medical Sciences; National Clinical Research Center for Interventional Medicine, Shanghai, China.

Objectives: The ValveClamp system (Hanyu Medical Technology) is a novel transcatheter edge-to-edge repair (TEER) system designed for ease of operation; however, there is a lack of data on its application in secondary mitral regurgitation (SMR). The authors report the mid-term outcomes of TEER using the ValveClamp system in SMR.

Methods: The study prospectively analyzed consecutive severe SMR patients who underwent transapical ValveClamp implantation at 10 Chinese centers.

View Article and Find Full Text PDF

One of the major issues encountered in patients undergoing evaluation for Transcatheter mitral valve replacement (TMVR) is the risk of Left ventricular outflow tract (LVOT) obstruction. LVOT obstruction is a catastrophic complication of TMVR, the result of displacement of the anterior mitral valve leaflet (AML) toward the interventricular septum. Several strategies to mitigate the risk of LVOT obstruction have been described and include percutaneous laceration of the anterior mitral leaflet (LAMPOON), alcohol septal ablation, trans-atrial leaflet modification (SITRAL) and Balloon Assisted Translocation of Mitral Anterior leaflet to prevent LVOT obstruction (BATMAN).

View Article and Find Full Text PDF

Patients with end-stage kidney disease (ESRD) represent a high-risk population in terms of both development of and death by cardiovascular diseases. Outcome data of ESRD patients with severe aortic valve stenosis (AS) treated by transcatheter aortic valve implantation (AVI) are scarce. We aim to compare the outcome of ESRD patients undergoing transfemoral (TF) or transapical (TA) AVI.

View Article and Find Full Text PDF

Purpose: To report the outcomes of the early feasibility study of transapical transcatheter mitral valve replacement (TMVR) with the SATURN System (InnovHeart, Milano, Italy) to treat patients with severe functional mitral regurgitation.

Description: Five high surgical risk patients underwent transapical transcatheter mitral valve replacement with the SATURN System at a single center. One-year follow-up is complete for all patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?