Introduction: Recurrent corneal erosion occurs when the wounded corneal epithelium failed to adhere to the underlying stroma. Therefore, this work aimed to assess the effect of treatment of corneal injury using Q- switched Nd:YAG laser.
Method: Twenty one New Zealand male rabbits weighing 2-2.5 kg and 3 months old were classified into three main groups. The control group: did not received any treatment (n=3 rabbits). The rest of the animals (n= 18 rabbits), corneal epithelium was injured by syringe needle and blade 15 and divided into:(A) Normal healing group: which was divided into three subgroups (n=3 rabbits each), and the animals were left for normal healing for1 day, 1 week, and 4 weeks respectively, (B) Laser treated group: divided into three subgroups (n=3 rabbit seach) and subjected to anterior stromal puncture using Q-switched Nd: YAG laser on corneal sub-epithelium or superficial stroma, and the animals were left for 1 day, 1 week, and 4 weeksrespectively. After the demonstrated periods, the corneas were isolated for estimation of total protein content, sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE), total antioxidative capacity (TAC), total oxidative capacity (TOC) and oxidative stress index (OSI).
Results: The present results of corneal total protein showed increment in the percentage change in normal healed groups after 1 day, 1 week and 4 weeks by values of 93%, 68% and 39%. In Q-switched Nd: YAG laser treated group the results showed better improvement in corneal protein than normal healed group with percentage changes of 58%, 29%, and 7.5% respectively. In SDS- PAGE, a protein band at 110 KD appeared in the migrating epithelium for both normal healed group and Q-switched Nd:YAG laser treated group with changes in the peaks intensities at middle and low molecular weight regions. Moreover, after 4 weeks the peak at 110 KD disappeared in the wounded epithelium treated with Q-switched Nd:YAG. After four weeks, the OSI in laser treated corneas showed pronounced balance between antioxidative capacityand oxidative capacity.
Conclusion: Anterior stromal puncture by Q-switched Nd:YAG laser is an effective, simple, safe and promising procedure to treat recurrent corneal erosion than normal healing.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4281999 | PMC |
Lasers Med Sci
November 2024
Dermatology Department, Kasr alainy Faculty of Medicine, Cairo University, Cairo, Egypt.
Treatment of onychomycosis includes topical and systemic agents. However, prolonged use of oral treatment could cause adverse effects and topical antifungal agents have limited penetration. To compare the clinical efficacy and the safety of fractional CO laser combined with topical tioconazole nail solution versus Q-switched 1064 Nd: YAG laser in the treatment of fingernail onychomycosis.
View Article and Find Full Text PDFJ Cosmet Dermatol
January 2025
Department of Dermatology, Faculty of Medicine, Balikesir University, Balikesir, Turkiye.
Lasers Med Sci
August 2024
Dermatology and Venereology, Faculty of Medicine, Tanta University, Tanta, El-Gharbia, Egypt.
Tattoo removal is considered a challenging field in cosmetic dermatology. Picosecond Q-switched Nd-YAG lasers targeting unique chromophores effectively manage this condition without serious complications. To evaluate the efficacy and safety of Picosecond Q-switched Nd-YAG laser in the treatment of black tattoos in the skin of middle eastern mostly skin type IV.
View Article and Find Full Text PDFLasers Med Sci
July 2024
Ministry of Health, Jamal Abdel Nasser street, PO Box 5, Sulibikhat, 2170, Kuwait.
Objective: To determine the effectiveness of picosecond KTP in reducing peri-ocular dark circles caused mainly by excessive pigmentation and to compare Picosecond KTP with Thulium laser ability in reducing the intensity and extent of peri-ocular dark circles.
Materials And Methods: This split-face prospective study included twelve women with periorbital dark circles (pigmented or mixed-pigmented type). The left lower eyelid was treated using the PicoHi machine (HIRONIC Ltd), a full beam Q-switched Nd-YAG provided by KTP crystal (523 nm) at settings of 0.
J Cutan Aesthet Surg
January 2024
Department of Skin & V. D., Civil Hospital, B. J. Medical College, Ahmedabad, Gujarat, India.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!