A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Value of intra- and post-operative cone beam computed tomography (CBCT) for positioning control of a sphenopalatine ganglion neurostimulator in patients with chronic cluster headache. | LitMetric

Introduction: The objective of this study was to determine whether postoperative control of the neurostimulator placement within the pterygopalatine fossa (PPF) by means of 3-dimensional (3D) cone beam computed tomography (CBCT) was of therapeutic relevance compared to intraoperative CBCT imaging alone.

Material And Methods: Immediately after implantation of the sphenopalatine ganglion (SPG) neurostimulator, intraoperative CBCT datasets were generated in order to visualize the position of the probe within the PPF. Postoperatively, all patients received a CBCT for comparison with intraoperatively acquired radiographs.

Results: Twenty-four patients with cluster headache (CH) received an SPG neurostimulator. In 4 patients, postoperative CBCT images detected misplacement not found in intraoperative CBCT. In 3 cases, electrode tips were misplaced into the maxillary sinus and in 1 case into the apex of the PPF superior to the suspected location of the SPG. Immediate revision with successful repositioning within 3 days was done in 2 patients and a deferred reimplantation in 1 patient within 6 months. One patient declined revision.

Conclusion: We were able to demonstrate the clinical value of postoperative dental CBCT imaging with a wide region of interest (ROI) due to a superior image quality compared with that achieved with intraoperative medical CBCT. Although intraoperative 3D CBCT imaging of electrode placement is helpful in the acute surgical setting, resolution is, at present, too low to safely exclude misplacement, especially in the maxillary sinus. High-resolution postoperative dental CBCT allows rapid detection and revision of electrode misplacement, thereby avoiding readmission and recurrent tissue trauma.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcms.2014.12.017DOI Listing

Publication Analysis

Top Keywords

intraoperative cbct
16
cbct imaging
12
cbct
11
cone beam
8
beam computed
8
computed tomography
8
tomography cbct
8
sphenopalatine ganglion
8
neurostimulator patients
8
cluster headache
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!