Development and validation of a LC-MS/MS method for the quantitation of lumefantrine in mouse whole blood and plasma.

J Chromatogr B Analyt Technol Biomed Life Sci

Division of Clinical Pharmacology, Department of Medicine, University of Cape Town, Medical School, Cape Town 7925, South Africa.

Published: March 2015

A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantitation of the antimalarial drug, lumefantrine (LF), in mouse whole blood and plasma. The analyte was extracted using a protein precipitation method followed by chromatographic separation on a Phenomenex Luna, PFP (50mm×2.0mm, 5μm) analytical column with a mobile phase consisting of acetonitrile and 0.1% formic acid (formic acid:water, 1:1000, v/v) at a ratio of 3:7 (v/v), delivered at a constant flow rate of 0.5ml/min. Stable isotope labeled lumefantrine (D9-LF) was used as the internal standard. Multiple reaction monitoring was performed using the transitions m/z 530.1→m/z 347.9 and m/z 539.1→m/z 347.9 for the quantification of LF and D9-LF, respectively. Calibration curves were constructed over the concentration range 15.6-4000ng/ml. The mean intra- and inter-assay accuracy values for the analysis of LF in WB was 103% (%CV=5.5) and 99.5% (%CV=5.5), respectively. The mean intra- and inter-assay accuracy values for the analysis of LF in plasma was 93.7% (%CV=3.5) and 93.9% (%CV=5.5), respectively. No significant matrix effect was observed during the method validation. The validated method was applied to an absorption study in mice, to determine and compare LF concentrations in whole blood and plasma samples. Results of the statistical analysis using a linear mixed effects growth curve model concluded that there was no significant difference (p-value=0.668) between WB and plasma LF concentrations. This method utilizes a small sample volume of 20μl, facilitating low blood collection volumes and a short chromatographic run time of 3min which allows for high sample throughput analysis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2015.01.015DOI Listing

Publication Analysis

Top Keywords

blood plasma
12
lc-ms/ms method
8
lumefantrine mouse
8
mouse blood
8
intra- inter-assay
8
inter-assay accuracy
8
accuracy values
8
values analysis
8
method
6
plasma
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!