Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Frequent nightly home hemodialysis (NHHD) has emerged as an attractive alternative to thrice weekly in-center hemodialysis, albeit with preponderant long-term hemodialysis catheter used. Sixty-three NHHD patients from University of Virginia Lynchburg Dialysis Facility were matched 1:2 with 121 conventional hemodialysis patients admitted to Fresenius Medical Care North America facilities from January 1, 2007 to December 31, 2010. Matching considered age (± 5 years), gender, race, dialysis vintage, and diabetes. The primary end-point was the combined incidence of bacteremia/sepsis, for up to 20 months or upon changing to a fistula/graft (with catheter removal), transferring to peritoneal dialysis (PD), or at the time of kidney transplant or death. No significant differences were observed in rate of fistula/graft conversion, transfer to PD, transplant, or death between NHHD and in-center hemodialysis (IHD) groups. For the first catheter used, the rate of catheter-related sepsis was not significantly different between the NHHD (1.77 per 100 patient months) and IHD (2.03 per 100 patient months; P = 0.21). Combining all catheters, the rate of bacteremia/sepsis per 100 patient months in the NHHD group was 1.51 and in the IHD group was 2.01 (P = 0.35). Median catheter lifespan for the first catheter was 5.6 (1.7∼19.0) for NHHD and 4.6 (2.7∼7.8) for the IHD group (P = 0.64), and for all catheters used was 5.2 (Q1∼Q3 = 1.5∼15.2) months in NHHD group, and 4.1 (2.0∼6.8) months in IHD group (P = 0.20). The rate of bacteremia and death is not different for up to 20 months in catheter users who dialyze via frequent NHHD vs. thrice weekly IHD.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/hdi.12245 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!