Impact and natural history of postprocedural aortic regurgitation on early and midterm mortality following transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis.

J Cardiovasc Med (Hagerstown)

aInterventional Cardiology Unit, San Raffaele Scientific Institute bInterventional Cardiology Unit, EMO-GVM Centro Cuore Columbus cDivision of Cardiac Surgery, San Raffaele Scientific Institute, Milan, Italy *Dr Alfonso Ielasi and Dr Azeem Latib contributed equally to the article and are joint first authors.

Published: April 2015

Background: Post-procedural aortic regurgitation (AR) negatively impacts the prognosis after trans-catheter aortic valve implantation. However, data evaluating the impact of different post-procedural AR grades (particularly mild) on clinical outcomes are still important.

Aim And Methods: A retrospective cohort analysis was performed on all consecutive patients with severe aortic stenosis who underwent trans-catheter aortic valve implantation between July 2008 and August 2011 in a single Institution. Aim of the study was to evaluate the impact of different post-procedural AR grades on early and mid-term clinical outcomes.

Results: 322 consecutive patients were evaluated. At post-procedural echocardiographic evaluation: 105 (32.6%) patients had no AR, 204 (63.4%) mild AR and 13 (4%) moderate/severe AR. In-hospital mortality was higher in patients with moderate/severe AR than in those with absent or mild AR (38.5% vs. 2.6%, P < 0.001). At a median clinical follow-up of 342 days [interquartile range 93-485] cardiovascular mortality was 2.9% in patients without AR; 13.2% in the mild AR group (P = 0.004 vs. absent AR) and 46.2% in the moderate/severe AR group (P < 0.001 vs. mild or absent AR). On multivariable analysis, post-procedural AR (hazard ratio = 2.65 absent vs. present any grade, 95% confidence interval = 1.11-6.29; P = 0.027) was an independent predictor of mid-term mortality.

Conclusions: The impact of post-procedural AR on outcomes after trans-catheter aortic valve implantation is proportional with its grade even in case of mild post-procedural AR compared to absent. This study confirms that every effort should be made to reduce the grade of post-procedural AR after trans-catheter aortic valve implantation with current devices.

Download full-text PDF

Source
http://dx.doi.org/10.2459/JCM.0000000000000249DOI Listing

Publication Analysis

Top Keywords

aortic valve
12
valve implantation
12
aortic regurgitation
8
patients severe
8
severe aortic
8
aortic stenosis
8
trans-catheter aortic
8
impact post-procedural
8
post-procedural grades
8
consecutive patients
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!