Fifty-five hips undergoing acetabular reconstruction with trabecular metal (TM)-coated cup and TM augments were reviewed at an average follow up of 53.7 months (36-91). Bony defects were Paprosky type IIIA in 42 and type IIIB without pelvic discontinuity in 13 hips. The average HHS increased from 40 (27-52) preoperatively to 90.5 (61-100) postoperatively (P<0.0001). Four (7.3%) of 55 hips underwent acetabular components revision: three cases of loosening (5.4%), and one of recurrent instability (1.8%) were reported. Survival rate at 2 and 5 years was 96.4% and 92.8%. In conclusion, the use of TM-coated cups and augments could be considered an effective management of Paprosky type III defects without pelvic discontinuity providing good clinical and radiographic outcomes in the mid term.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.arth.2015.01.001 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!