The Physikalisch-Technische Bundesanstalt (PTB) has a long tradition in the calibration of radiation sources in the ultraviolet and vacuum ultraviolet spectral range, with traceability to calculable synchrotron radiation. Within this context, new instrumentation in the PTB laboratory at the Metrology Light Source (MLS) has been put into operation that opens up extended and improved calibration possibilities. A new facility for radiation source calibrations has been set up in the spectral range from 7 nm to 400 nm based on a combined normal incidence-grazing incidence monochromator. The facility can be used for the calibration of transfer sources in terms of spectral radiant intensity or mean spectral radiance, with traceability to the MLS primary source standard. We describe the design and performance of the experimental station and give examples of some commissioning results.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1063/1.4905187 | DOI Listing |
ACS Appl Bio Mater
January 2025
Department of Materials Science and Engineering, and Centre for Functional Photonics (CFP), City University of Hong Kong, Hong Kong SAR 999077, P. R. China.
Bioimaging probes based on carbon dots (CDs) can become a useful replacement for existing commercial probes, benefiting clinical diagnostics. While the development of dual-mode CD-based probes for magnetic resonance imaging (MRI), which provides the ability for photoluminescence (PL) detection at the same time, is ongoing, several challenges have to be addressed. First, most of the CD-based probes still emit at shorter wavelengths (blue/green spectral range), which is harmful to biological objects or have very low PL intensity in the biological window of tissue transparency (red/near-infrared spectral range).
View Article and Find Full Text PDFSci Rep
January 2025
Faculty of Electronics, Telecommunications and Informatics, Gdansk University of Technology, 80-233, Gdansk, Poland.
Computational tools, particularly electromagnetic (EM) solvers, are now commonplace in antenna design. While ensuring reliability, EM simulations are time-consuming, leading to high costs associated with EM-driven procedures like parametric optimization or statistical design. Various techniques have been developed to address this issue, with surrogate modeling methods garnering particular attention due to their potential advantages.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Physics, Indian Institute of Technology Roorkee, Roorkee, Uttarakhand, 247667, India.
This paper explores the development of an opto-thermal-electrical model for plasmonic Schottky solar cells (PSSCs) using a comprehensive multiphysics approach. We simulated the optical properties, power conversion efficiencies, and energy yield of PSSCs with varying nanoparticle (NP) configurations and sizes. Our spectral analysis focused on the absorption characteristics of these solar cells, examining systems sized 3 × 3, 5 × 5, and 7 × 7, with NP radii ranging from 10 to 150 nm.
View Article and Find Full Text PDFSci Total Environ
January 2025
Université du Québec à Trois-Rivières Trois-Rivieres, Quebec, Canada.
Management of heterogeneous construction, renovation, and demolition (CRD) wood residues in Québec brings into light, a widespread topic under discussion related to their current disposal methods in landfills, that may lead to environmental concerns. With rising forfeitures from a legal standpoint, alternative treatment methods for CRD wood wastes are being explored. Thermochemical biomass conversion techniques can be employed to depolymerize low-quality end-of-life CRD wood and valorize it to bio-based products.
View Article and Find Full Text PDFPLoS One
January 2025
Division of Cardiology, Department of Internal Medicine, Kaohsiung Medical University Gangshan Hospital, Kaohsiung, Taiwan.
Background/purpose: Dyslipidemia, a hallmark of metabolic syndrome (MetS), contributes to atherosclerotic and cardiometabolic disorders. Due to days-long analysis, current clinical procedures for cardiotoxic blood lipid monitoring are unmet. This study used AI-assisted attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy to identify MetS and precisely quantify multiple blood lipid levels with a blood sample of 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!