AI Article Synopsis

Article Abstract

This study assessed optic disc size and cupping, using a commercially available ophthalmoscope, in order to show norms of these values for clinical practice. Subjects were office-workers referred from their respective workplaces for a routine medical examination, which included eye examination. The optic disc size was classified as small, medium or large, for having a diameter < 1.0, 1.0-1.5, or > 1.5 times (respectively) the diameter of the ophthalmoscope's selected light spot on the posterior pole. The cupping was classified as the ratio of the vertical cupping diameter and the vertical disc diameter on a relative decimal scale from 0.0 to 1.0.This study included 184 subjects with a mean age of 40.5 ± 9.5 years; 149 (81%) were males. Their mean ocular pressure was 12.4 ± 1.5 mmHg (range 10-17 mmHg). There was a high correlation between optic disc sizes and cupping in the right and left eyes (Pearson Correlation r = 0.866, p < 0.001); therefore, for simplicity only the data for right eyes are presented. According to our definition, the optic discs in these eyes comprised 27 (14.7%) small, 141 (76.6%) medium and 16 (8.7%) large. The small optic discs were rarely cupped, and the large optic discs were always cupped. Optic disc cupping greater than 0.7 was rarely found and should be suspect of glaucoma. Clinical doctors should be aware of this and refer those subjects with abnormal cupping to the specialist.

Download full-text PDF

Source

Publication Analysis

Top Keywords

optic disc
16
optic discs
12
disc cupping
8
disc size
8
cupping
7
optic
7
disc
5
prevalence disc
4
cupping non-glaucomatous
4
eyes
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!