Comparison of two isometric handgrip protocols on sympathetic arousal in women.

Physiol Behav

University of Southern California, Davis School of Gerontology, Los Angeles, CA 90089, USA.

Published: April 2015

Isometric handgrip is commonly used in stress research because the task reliably increases sympathetic arousal. Various handgrip protocols have been used; they vary in handgrip strength, duration of grip, and the number of cycles of handgrip and rest. However, most protocols require the calibration of a maximum voluntary contraction (MVC) prior to the handgrip task, which is not always convenient (i.e., in a functional magnetic resonance imaging study). Here, we wanted to test whether two handgrip protocols with different strength, duration and cycle protocols would reliably elicit sympathetic arousal in the absence of calibrating an MVC. Sixty-two healthy naturally cycling women and women on hormonal contraception participated in one of the two isometric handgrip protocols using a hand therapy ball of medium resistance. Women completed one of the following handgrip protocols: 1) 30% of a perceived maximum voluntary contraction for 3 min or 2) 3 cycles of maximum voluntary contraction for 18s with a one minute rest in between. All handgrip blocks were counterbalanced with a control condition. Sympathetic arousal was measured throughout the session via pupil diameter changes and salivary alpha-amylase. Results indicate that in the absence of calibrating an MVC, the handgrip tasks elicited different changes in sympathetic arousal. Pupil dilation responses increased significantly in the handgrip versus control blocks only in participants in the 18-s protocol. Additionally, more participants exhibited a salivary alpha-amylase response to the handgrip block in the 18-s condition compared to the 3-min condition. Thus, these results suggest that neuroimaging and behavioral studies with isometric handgrip should be able to successfully induce sympathetic nervous activity with the 18-s paradigm, regardless of the handgrip device and the ability to calibrate an MVC.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4340716PMC
http://dx.doi.org/10.1016/j.physbeh.2015.01.031DOI Listing

Publication Analysis

Top Keywords

handgrip protocols
20
sympathetic arousal
20
isometric handgrip
16
handgrip
15
maximum voluntary
12
voluntary contraction
12
strength duration
8
absence calibrating
8
calibrating mvc
8
salivary alpha-amylase
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!