Background: It is unknown if activity monitors can detect the increased energy expenditure (EE) of wheelchair propulsion at different speeds or on different surfaces.

Methods: Individuals who used manual wheelchairs (n = 14) performed 5 wheeling activities: on a level surface at 3 speeds, on a rubberized track at 1 fixed speed and on a sidewalk course at a self-selected speed. EE was measured using a portable indirect calorimetry system and estimated by an Actical (AC) worn on the wrist and a SenseWear (SW) activity monitor worn on the upper arm. Repeated- measures ANOVA was used to compare measured EE to the estimates from the standard AC prediction equation and SW using 2 different equations.

Results: Repeated-measures ANOVA demonstrated a significant main effect between measured EE and estimated EE. There were no differences between the criterion method and the AC across the 5 activities. The SW overestimated EE when wheeling at 3 speeds on a level surface, and during sidewalk wheeling. The wheelchair-specific SW equation improved the EE prediction during low intensity activities, but error progressively increased during higher intensity activities.

Conclusions: During manual wheelchair propulsion, the wrist-mounted AC provided valid estimates of EE, whereas the SW tended to overestimate EE.

Download full-text PDF

Source
http://dx.doi.org/10.1123/jpah.2014-0376DOI Listing

Publication Analysis

Top Keywords

wheelchair propulsion
12
activity monitors
8
energy expenditure
8
expenditure wheelchair
8
level surface
8
validity physical
4
physical activity
4
monitors estimating
4
estimating energy
4
propulsion background
4

Similar Publications

Background: Wheelchair users face various health issues, such as cardiac problems, obesity, tissue deformation, and shoulder and wrist injuries. Although the subject of ergometry is known since 1912 and the mechanic of propulsion gesture and wheelchair configuration has been studied over the years, most of the equipment found in the literature are adaptations or lack the tools for standardization of techniques. This paper aims to conduct biomechanical validation of a new wheelchair ergometer (ERGO1) designed for assessing physical fitness and muscle training of the upper limbs of people with disabilities.

View Article and Find Full Text PDF

Exploring the challenges in manual wheelchair operation for new users.

Disabil Rehabil Assist Technol

January 2025

School of Physical and Occupational Therapy, McGill University, Montreal, QC, Canada.

This exploratory qualitative study examines the challenges faced by manual wheelchair (MWC) users and their clinicians, with a focus on mobility difficulties in both outdoor and indoor environments, as well as training priorities. The study involved semi-structured interviews with 18 clinicians and 25 MWC users from various rehabilitation centres. The interviews, lasting between 30 and 60 minutes, explored specific aspects of MWC use, including mobility challenges, training needs, and psychological factors.

View Article and Find Full Text PDF

Wheelchair propulsion is a fundamental skill in wheelchair sports, particularly in wheelchair tennis. To achieve optimal mobility during wheelchair athletic performance, it is essential to consider propulsion techniques. This study examines the effect of push frequency and stroke duration on wheelchair maneuverability, measured by velocity during propulsion, among wheelchair tennis athletes.

View Article and Find Full Text PDF

Sitting pressure during wheelchair propulsion and handcycling: effects of backrest angle, movement intensity and cushion type.

Disabil Rehabil Assist Technol

November 2024

Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Amsterdam, The Netherlands.

The main aim of this study was to compare sitting pressure (peak pressure index (PPI) and peak pressure gradient (PPG)) between a daily wheelchair and fixed-frame handcycle, thereby assessing the effect of handcycle backrest angle, movement intensity and cushion type. Twenty able-bodied participants performed static and dynamic (two intensities) tests in a wheelchair and handcycle. A honeycomb wheelchair cushion and standard foam handcycle cushion were used.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to evaluate the impact of a 16-week exoskeleton-assisted walking program on upper limb strength, mass, and wheelchair propulsion skills in individuals with chronic spinal cord injuries who primarily use wheelchairs.
  • Conducted as a single-group pre-post intervention, the study involved ten participants with limited lower limb motor function, utilizing various tests to assess changes in muscle strength and wheelchair performance before and after the program.
  • Results showed a significant improvement only in the participants' natural velocity during a short wheelchair propulsion test, indicating more research is needed to explore how different training volumes might further enhance not just upper limb strength but also wheelchair skills, particularly in those less experienced with wheelchair use.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!