A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Improving the application of laser-induced breakdown spectroscopy for the determination of total carbon in soils. | LitMetric

Improving the application of laser-induced breakdown spectroscopy for the determination of total carbon in soils.

Environ Monit Assess

Department of Environmental Science and Engineering, Ewha Womans University, 52, Ewhayeodae-gil, Seodaemun-gu, Seoul, 120-750, Korea.

Published: February 2015

The increase of atmospheric greenhouse gases such as CO2 has caused noticeable climate change. Since increased CO2 may contribute to carbon storage in terrestrial ecosystems through the CO2 cycle between the atmosphere and vegetation, it is necessary to improve methods for measuring C in soil. In this study, we determined the total carbon concentrations of soils using a highly sensitive and rapid method, laser-induced breakdown spectroscopy. The presence of C has been measured by detecting signal at the wavelength of 247.86 nm. The obstacle of Fe interference at the C measurement wavelength of 247.86 nm was reduced by selecting the optimal delay time of 1.4 μs. The ratio of peak intensities (areas) at 247.86 nm for C and 248.20 nm for Fe was then successfully applied to the calibration curve. In addition, to dismiss the problem of measuring the C lines at 247.86 nm, 193.03 nm has been used to observe C emission. Both the 193.03- and 247.86-nm lines provided significant linear calibrations. The 193.03-nm lines presented stronger relative accuracies in predicting the lower C concentrations of the unknown samples than that one at 247.86 nm.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10661-015-4286-zDOI Listing

Publication Analysis

Top Keywords

laser-induced breakdown
8
breakdown spectroscopy
8
total carbon
8
wavelength 24786
8
0
5
improving application
4
application laser-induced
4
spectroscopy determination
4
determination total
4
carbon soils
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!