A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Esophageal covered stent fixation using an endoscopic over-the-scope clip. Mechanical proof of the concept and first clinical experience. | LitMetric

Background And Study Aims: Endoscopic suturing reduces stent migration, but is challenging and time-consuming. We compare endoscopic suturing versus anchoring with a novel over-the-scope clip (Padlock) to fix esophageal stents. Additionally, the first clinical case of Padlock stent fixation is reported.

Materials And Methods: A fully covered esophageal stent was placed in 11 pigs and fixed with one figure-of-eight suture (n = 5) or with a Padlock (n = 4) or not fixed (controls; n = 2). The force required to mobilize the stent was recorded.

Clinical Case: an esophageal stent was fixed with a Padlock and endoscopically removed 1 month later, in an 82-year-old patient.

Results: Mean force (newton) to mobilize the stent was similar after suturing and Padlock fixation (23.99 ± 14.91 vs. 19.97 ± 7.62; p = 0.32). In controls was 7 and 11 Newtons. Suturing time (seconds) was longer than Padlock application (455.4 ± 144.83 vs. 155 ± 12.9; p = 0.002).

Clinical Case: stent fixation was feasible and uncomplicated. Removal was easy, and only mild bleeding occurred.

Conclusions: Padlock is faster than endoscopic suturing and achieves similar stent fixation. The first clinical case confirms the feasibility of the method.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00464-015-4078-0DOI Listing

Publication Analysis

Top Keywords

stent fixation
16
endoscopic suturing
12
stent
9
over-the-scope clip
8
clinical case
8
esophageal stent
8
mobilize stent
8
padlock
7
fixation
5
suturing
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!