A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

High-pressure injection of glycerol with HybridKnife for ESD is feasible and increases the ease and speed of the procedure: an in vivo study in pigs and first use in human. | LitMetric

Background And Aims: The HybridKnife water-jet system (ERBE, Tubingen, Germany) has been shown to increase dissection speed and decreased the risk of perforation during endoscopic submucosal dissection (ESD). Glycerol mixture is a viscous, long-lasting solution preferentially used by Japanese ESD experts. The combination of the HybridKnife system with a glycerol solution has not been evaluated to date.

Materials And Methods: A prospective non-randomised comparative study of ESD with HybridKnife injecting of either a glycerol mixture or normal saline was performed. Twenty dissections (ten per group) were performed on four anaesthetised domestic mini-pigs. Dissection speed (mm(2)/min), size of the specimen (mm(2)), duration (min), en bloc resection rate, and bleeding and perforation rates were prospectively recorded. An evaluation of operator comfort and perception of safety (dissection score) was performed using a visual analogue scale with 0 being the worst score and 10 the best.

Results: High-pressure injection of the glycerol mixture and dissection with the HybridKnife was feasible without complications. Dissection was significantly more rapid (1.67-fold) with glycerol injection than normal saline injection (27.44 vs. 16.44 mm(2)/min; p < 0.001). The dissection score was significantly higher in the glycerol group than in the normal saline group (5.9 vs. 2.9; p < 0.001). No differences were observed in the rates of en bloc resection, bleeding and perforation. Seven first human cases were also easy without need of preliminary incision and technical complication.

Conclusion: High-pressure jet injection of glycerol with HybridKnife for ESD is feasible and increases the speed and safety of the procedure compared with use of normal saline.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00464-015-4072-6DOI Listing

Publication Analysis

Top Keywords

glycerol mixture
12
high-pressure injection
8
injection glycerol
8
dissection speed
8
normal saline
8
glycerol
6
dissection
6
hybridknife
5
glycerol hybridknife
4
esd
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!