Objectives: Compare seven previous methods for the estimation of aortic characteristic impedance, which contributes to left ventricle pulsatile load, from phase-contrast cardiovascular magnetic resonance (CMR) and applanation tonometry data.
Methods: We studied 77 healthy (43 ± 16 years) individuals and 16 hypertensive (61 ± 9 years) patients, who consecutively underwent ascending aorta CMR and carotid tonometry, resulting in flow and pressure waveforms, respectively. Characteristic impedance was semi-automatically estimated in time domain from these latter waveforms, using seven methods. The methods were based on the following: methods 1-4, magnitudes at specific times; method 5, early-systolic up-slope; method 6, time-derivatives peak; and method 7, pressure-flow loop early-systolic slope.
Results: Aortic characteristic impedance was significantly increased in hypertensive patients when compared to elderly controls (n = 32) with a similar mean age of (59 ± 8 years) when using methods based on 95% of peak flow, up-slopes, and derivatives peaks (P < 0.05). When considering healthy individuals, impedance indices were significantly correlated to central pulse pressure for all methods (P < 0.005). Finally, characteristic impedance was correlated to the frequency-domain reference values (r > 0.65, P < 0.0001), with a slight superiority for the same three methods as above (r > 0.82, P < 0.0001).
Conclusions: This is the first study demonstrating phase-contrast CMR and tonometry usefulness in aortic characteristic impedance temporal estimation. Methods based on 95% of peak flow, as well as those based on derivative peaks and up-slopes, which are fast and independent of curve preprocessing, were slightly superior. They can be easily integrated in a clinical workflow and may help to understand the complementarity of this pulsatile index with other CMR aortic geometry and stiffness measures in the setting of left ventricle-aortic coupling.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/HJH.0000000000000448 | DOI Listing |
Geriatr Gerontol Int
January 2025
Department of Rehabilitation Medicine, Hyogo Medical University, Nishinomiya, Japan.
Aim: One of the parameters that is measurable using bioelectrical impedance is the phase angle (PhA), which is an indicator of skeletal muscle quality. The PhA reflects cellular health and nutritional status and is an important parameter for monitoring recovery after stroke. However, the factors affecting skeletal muscle quality remain unclear.
View Article and Find Full Text PDFJ Phys Condens Matter
January 2025
Nanjing University, Hankou Road 22, School of Physics, Nanjing University, Nanjing, Jiangsu, 210093, CHINA.
Driven by the miniaturization of microelectronic devices and their multifunctionalities, the development of new quadruple-perovskite oxides with high dielectric constants and high Curie temperature are highly required. Herein, we report on the structural, dielectric and magnetic properties of Sb/Cr-doped CaCu3Ti4O12 (CCTO) quadruple perovskite oxides, CaCu3Ti3.9Sb0.
View Article and Find Full Text PDFClin Nutr ESPEN
December 2024
Hacettepe University, Faculty of Medicine, Department of Neurology, Ankara, Turkey; Hacettepe University Faculty of Medicine, Department of Neurology, Neurology Intensive Care Unit, Stroke Unit, Ankara. Electronic address:
Background: Premorbid sarcopenia, osteoporosis, and obesity are epiphenomena that affect survival and functional outcomes in patients with acute ischemic stroke. The effects of preexisting sarcopenia and/or osteopenia on long-term outcome after ischemic stroke were herein prospectively studied.
Methods: Dual-energy x-ray absorptiometry (DeXA), bio-impedance analysis (BIA) and muscle ultrasonography (US) data were prospectively collected within the first 72 hours in 297 consecutive acute ischemic stroke patients (45.
Small Methods
December 2024
Department of Advanced Materials for Energy Applications, Catalonia Institute for Energy Research (IREC), Jardins de les Dones de Negre 1, Sant Adrià del Besòs, Barcelona, 08930, Spain.
Functional properties of mixed ionic electronic conductors (MIECs) can be radically modified by (de)insertion of mobile charged defects. A complete control of this dynamic behavior has multiple applications in a myriad of fields including advanced computing, data processing, sensing or energy conversion. However, the effect of different MIEC's state-of-charge is not fully understood yet and there is a lack of strategies for fully controlling the defect content in a material.
View Article and Find Full Text PDFNeurogastroenterol Motil
December 2024
Division of Gastroenterology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Background: According to the Lyon Consensus 2.0, mean nocturnal baseline impedance (MNBI) greater than 2500 Ω is considered evidence against gastroesophageal reflux disease (GERD). However, we have observed that a subset of GERD patients presents with MNBI exceeding 2500 Ω.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!