A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A method of detecting heartbeat locations in the ballistocardiographic signal from the fiber-optic vital signs sensor. | LitMetric

We present a flexible, easy-to-expand digital signal processing method for detecting heart rate (HR) for cardiac vibration signals of fiber Bragg grating (FBG) sensor. The FBG-based method of measuring HR is possible to use during the magnetic resonance imaging procedure, which is its unique advantage. Our goal was to design a detection method with plurality of parameters and to subject these parameters to genetic algorithm optimization technique. In effect, we arrived at a method that is well able to deal with much distorted signals with low SNR. We proved that the method we developed allows automatic adjustment to the shape of the waves of signal carrying useful information about the moments of heartbeat. Thus, we can easily adapt our technique to the analysis of signals, which contains information on HR, from sensors employing different techniques of strain detection. The proposed method has the capabilities of analyzing signals in semi-real-time (online) with beat-to-beat resolution, significantly low delay, and negligible computational power requirements. We verified our method on recordings in a group of seven subjects. Verification included over 6000 heartbeats (82 min 47 s of recordings). The root-mean-square error of our method does not exceed 6.0 bpm.

Download full-text PDF

Source
http://dx.doi.org/10.1109/JBHI.2015.2392796DOI Listing

Publication Analysis

Top Keywords

method
9
method detecting
8
detecting heartbeat
4
heartbeat locations
4
locations ballistocardiographic
4
ballistocardiographic signal
4
signal fiber-optic
4
fiber-optic vital
4
vital signs
4
signs sensor
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!