A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

One-step synthesis of potassium ferricyanide-doped polyaniline nanoparticles for label-free immunosensor. | LitMetric

One-step synthesis of potassium ferricyanide-doped polyaniline nanoparticles for label-free immunosensor.

Biosens Bioelectron

School of Pharmaceutical Sciences, Sun Yat-sen University, Guangzhou 510006, China. Electronic address:

Published: June 2015

A novel, label-free and inherent electroactive redox immunosensor for ultrasensitive detection of carcinoembryonic antigen (CEA) was proposed based on gold nanoparticles (AuNPs) and potassium ferricyanide-doped polyaniline (FC-PANI) nanoparticles. FC-PANI composite was synthesized via oxidative polymerization of aniline, using potassium ferricyanide (K3[Fe(CN)6]) as both oxidant and dopant. FC-PANI acting as the signal indicator was first fixed on a gold electrode (GE) to be the signal layer. Subsequently, the negatively charged AuNPs could be adsorbed on the positively charged FC-PANI modified GE surface by electrostatic adsorption, and then to immobilize CEA antibody (anti-CEA) for the assay of CEA. The CEA concentration was measured through the decrease of amperometric signals in the corresponding specific binding of antigen and antibody. The wide linear range of the immunosensor was from 1.0 pg mL(-1) to 500.0 ng mL(-1) with a low detection limit of 0.1 pg mL(-1) (S/N=3). The proposed method would have a potential application in clinical immunoassays with the properties of facile procedure, stability, high sensitivity and selectivity.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2015.01.018DOI Listing

Publication Analysis

Top Keywords

potassium ferricyanide-doped
8
ferricyanide-doped polyaniline
8
one-step synthesis
4
synthesis potassium
4
polyaniline nanoparticles
4
nanoparticles label-free
4
label-free immunosensor
4
immunosensor novel
4
novel label-free
4
label-free inherent
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!