A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of coronary adventitial vasa vasorum using 3D optical coherence tomography--animal and human studies. | LitMetric

Objectives: This study sought to evaluate adventitial vasa vasorum (VV) in vivo with novel imaging technique of optical coherence tomography (OCT).

Methods: To verify OCT methods for quantification of VV, we first studied 2 swine carotid arteries in a model of focal angiogenesis by autologous blood injection, and compared microchannel volume (MCV) by OCT and VV by m-CT, and counts of those. In OCT images, adventitial MC was identified as signal-voiding areas which were located within 1 mm from the lumen-intima border. After manually tracing microchannel areas and the boundaries of lumen-intima and media-adventitial in all slices, we reconstructed 3D images. Moreover, we performed with OCT imaging in 8 recipients referred for evaluation of cardiac allograft vasculopathy at 1 year after heart transplantation. MCV and plaque volume (PV) were assessed with 3D images in each 10-mm-segment.

Results: In the animal study, among the 16 corresponding 1-mm-segments, there were significant correlations of count and volume between both the modalities (count r(2) = 0.80, P < 0.01; volume r(2) = 0.50, P < 0.01) and a good agreement with a systemic bias toward underestimation with m-CT. In the human study, there was a significant positive correlation between MCV and PV (segment number = 24, r(2) = 0.63, P < 0.01).

Conclusion: Our results suggest that evaluation of MCV with 3D OCT imaging might be a novel method to estimate the amount of adventitial VV in vivo, and further has the potential to provide a pathophysiological insight into a role of the VV in allograft vasculopathy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4494669PMC
http://dx.doi.org/10.1016/j.atherosclerosis.2015.01.016DOI Listing

Publication Analysis

Top Keywords

adventitial vasa
8
vasa vasorum
8
optical coherence
8
evaluation coronary
4
coronary adventitial
4
vasorum optical
4
coherence tomography--animal
4
tomography--animal human
4
human studies
4
studies objectives
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!