Impact of water management practice scenarios on wastewater flow and contaminant concentration.

J Environ Manage

College of Engineering and Science, Victoria University, PO Box 14428, Melbourne, VIC 8001, Australia; Institute for Sustainability and Innovation, Victoria University, PO Box 14428, Melbourne, VIC 8001, Australia.

Published: March 2015

Due to frequent droughts and rapid population growth in urban areas, the adoption of practices to reduce the usage of fresh water is on the rise. Reduction in usage of fresh water can be achieved through various local water management practices (WMP) such as Water Demand Management (WDM) and use of alternative water sources such as Greywater Recycling (GR) and Rainwater Harvesting (RH). While the positive effects of WMPs have been widely acknowledged, the implementation of WMPs is also likely to lower the wastewater flow and increase the concentration of contaminants in sewage. These in turn can lead to increases in sewer problems such as odour and corrosion. This paper analyses impacts of various WMP scenarios on wastewater flow and contaminant load. The Urban Volume and Quality (UVQ) model was used to simulate wastewater flow and the associated wastewater contaminants from different WMP scenarios. The wastewater parameters investigated were those which influence odour and corrosion problems in sewerage networks due to the formation of hydrogen sulphide. These parameters are: chemical oxygen demand (COD), nitrate (NO3(-)), sulphate (SO4(2-)), sulphide (S(2-)) and iron (Fe) that were contributed by the households (not including the biochemical process in sewer pipe). The results will help to quantify the impact of WMP scenarios on odour and corrosion in sewerage pipe networks. Results show that the implementation of a combination of WDM and GR had highly increased the concentration of all selected contaminant that triggered the formation of hydrogen sulphide, namely COD, sulphate and sulphide. On the other hand, the RH scenario had the least increase in the concentration of the contaminants, except iron concentrations. The increase in iron concentrations is actually beneficial because it inhibits the formation of hydrogen sulphide.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jenvman.2014.12.010DOI Listing

Publication Analysis

Top Keywords

wastewater flow
16
scenarios wastewater
12
odour corrosion
12
wmp scenarios
12
formation hydrogen
12
hydrogen sulphide
12
water management
8
flow contaminant
8
usage fresh
8
fresh water
8

Similar Publications

Characterisation and anaerobic digestion of fat, oil and grease (FOG) waste from wastewater treatment plants.

J Environ Manage

January 2025

Department of Civil, Environmental and Architectural Engineering, University of Padova, Via Marzolo 9, 35131, Padova, Italy.

The materials removed in the oil separation units of wastewater treatment plants can be referred to as fat, oil and grease (FOG) waste. FOG waste accumulation in treatment plants can cause clogging of pipes, production of excessive scums and foams, and negatively affect air/liquid oxygen transfer. While conventional disposal routes of this material can be limited by its water and organic content, FOG can represent a source of bio-energy other than bio-diesel production.

View Article and Find Full Text PDF

Understanding bacterial ecology to combat antibiotic resistance dissemination.

Trends Biotechnol

January 2025

School of Civil and Environmental Engineering, University of New South Wales, Sydney, New South Wales 2052, Australia. Electronic address:

The dissemination of antibiotic resistance from environmental sources is a growing concern. Despite the widespread occurrence of antibiotic resistance transmission events, there are actually multiple obstacles in the ecosystem that restrict the flow of bacteria and genes, in particular nonnegligible biological barriers. How these ecological factors help combat the dissemination of antibiotic resistance and relevant antibiotic resistance-diminishing organisms (ARDOs) deserves further exploration.

View Article and Find Full Text PDF

Determination of main influence mechanism of fulvic acid on arsenic removal by ferric chloride.

J Environ Sci (China)

July 2025

John A. Reif, Jr. Department of Civil and Environmental Engineering, New Jersey Institute of Technology, Newark, New Jersey 07102, USA.

In this study, synthetic wastewater containing 110 µg/L arsenate (As(V)), 0-20 mg/L fulvic acid (FA), and 0-12.3 mg/L phosphate was treated with 3 mg/L Fe. The mechanisms of FA and phosphate effects on As(V) removal by ferric chloride were determined using 0.

View Article and Find Full Text PDF

Investigating the application of novel filling materials in Vertical Subsurface Flow Constructed Wetlands for the treatment of anaerobic effluents originating from domestic wastewater.

J Environ Manage

January 2025

Sanitary Engineering Laboratory, Department of Water Resources and Environmental Engineering, School of Civil Engineering, National Technical University of Athens, 9 Iroon Polytechniou St., Zographou Campus, 15773, Athens, Greece.

Vertical subsurface flow constructed wetlands (VSSF CWs) were employed to investigate the use of biochar that could be produced with local agricultural biomass through pyrolysis, recycled glass from local recycling companies and gel beads with decreased packing volume and shipping cost as substrate alternatives to sand. The materials were assessed in terms of granulometry, porosity, adsorption capacity and hydraulic conductivity and were used for the treatment of an upflow anaerobic sludge blanket (UASB) reactor, treating domestic wastewater, effluent. Granulometry was a major factor impacting TSS removal that ranged from 81% ± 10% to 97% ± 2%.

View Article and Find Full Text PDF

Aerosol particles released from grit chambers of nine urban wastewater treatment plants in typical regions: Fugitive characteristics, quantitative drivers, and generation process.

Water Res

January 2025

State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco- Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing 100049, China. Electronic address:

The flow through the grit chamber is non-biochemically treated wastewater, which contains microorganisms mainly from the source of wastewater generation. There are limited reports on aerosol particles generated by grit chambers compared with those produced by biochemical treatment tanks. This study analyzed the fugitive characteristics of aerosol particles produced in grit chambers at nine wastewater treatment plants in three regions of China.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!