Implantation failure is a major limiting factor in assisted reproduction improvement. Dysfunction of embryo-maternal immuno-tolerance pathways may be responsible for repeated implantation failures. This fact is supported by immunotropic theory stipulating that maternal immune cells, essentially uterine CD56+ natural killer cells, are determinants of implantation success. In order to test this hypothesis, we applied endometrium immuno-modulation prior to fresh embryo transfer for patients with repeated implantation failures. Peripheral blood mononuclear cells were isolated from repeated implantation failure patients undergoing assisted reproductive technology cycles. On the day of ovulation induction, cells were isolated and then cultured for 3 days and transferred into the endometrium cavity prior to fresh embryo transfer. This immunotherapy was performed on 27 patients with repeated implantation failures and compared with another 27 patients who served as controls. Implantation and clinical pregnancy were increased significantly in the peripheral blood mononuclear cell test versus control (21.54, 44.44 vs. 8.62, 14.81%). This finding suggests a clear role for endometrium immuno-modulation and the inflammation process in implantation success. Our study showed the feasibility of intrauterine administration of autologous peripheral blood mononuclear cells as an effective therapy to improve clinical outcomes for patients with repeated implantation failures and who are undergoing in vitro fertilization cycles.

Download full-text PDF

Source
http://dx.doi.org/10.1017/S0967199414000719DOI Listing

Publication Analysis

Top Keywords

repeated implantation
24
implantation failures
20
peripheral blood
16
blood mononuclear
16
patients repeated
16
mononuclear cells
12
embryo transfer
12
implantation
10
implantation failure
8
implantation success
8

Similar Publications

The number of beef × dairy animals entering feedlots has increased, but the response of beef × dairy cattle to growth-promoting implants has not been well characterized. The objective of this study was to evaluate the effects of breed type and implant administration on live performance, carcass characteristics, sera metabolites, and immunohistochemical (IHC) outcomes. Forty-eight steers (average body weight [BW] = 417±22 kg) were sorted by breed into groups of predominantly Angus (B), black-hided beef × primarily Holstein (B×D), or Holstein (D), and half of the steers within each breed type were administered a steroidal implant.

View Article and Find Full Text PDF

Statement Of The Problem: Previous longitudinal studies have found that patients with shortened dental arches (SDA) have a higher risk of long-term tooth loss than complete dental arch (CDA). However, the difference between SDA and CDA concerning oral function has yet to be demonstrated.

Purpose: We aimed to clarify the influence of molar occlusal support on oral function in SDA and CDA participants cross-sectionally and longitudinally.

View Article and Find Full Text PDF

Hyperelastic materials are extensively incorporated in medical implants and microelectromechanical systems due to their large, elastic, recoverable strains. However, their mechanical properties are sensitive to processing parameters that may lead to inconsistent characterization. Various test setups have been employed for characterizing hyperelastic materials; however, they are often costly.

View Article and Find Full Text PDF

Background: Acellular dermal matrix (ADM) has been introduced as an alternative to autogenous grafts. This study assessed the biological behavior of mesenchymal stem cells (MSCs) on two types of commercial ADM scaffolds.

Methods: The present in vitro study investigated the behavior of MSCs cultured on scaffold type I CenoDerm® (Tissue Regeneration Corporation) and type II Acellular Dermis (Iranian Tissue Product Co.

View Article and Find Full Text PDF

The popliteal artery segment is particularly challenging for endovascular treatment. Stents used for treating popliteal artery lesions are usually associated with an increased risk of stent fracture and re-occlusion. The Supera stent is designed to withstand mechanical stress, with a low risk of fracture.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!