A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Shoulder joint dislocation as an unusual complication of defibrillation threshold testing following subcutaneous implantable cardioverter-defibrillator implantation. | LitMetric

A 53-year-old man underwent implantation of a totally subcutaneous ICD (S-ICD; Boston Scientific). He was positioned supine, with the left arm abducted, externally rotated (i.e. palm up) and strapped to the arm extender. The generator was placed in the left mid-axillary line along the 5th-6th intercostal spaces and the defibrillation coil was tunneled anterior to the sternum. Defibrillation threshold (DFT) testing with 65 Jcaused a forceful pectoralis twitch. The patient woke up with a painful anteriorly dislocated left shoulder. Glenohumeral dislocation due to DFT testing has not been previously reported. It is likely that this complication is specific to the S-ICD implantation, and is related to positioning with the arm abducted, externally rotated, and immobilized, and use of greater defibrillation energy with current pathway through the bulk of the pectoralis muscle.Precautions may include extending the arm palm down, strapping the arm loosely, and adduction of the arm for DFT testing.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4286953PMC
http://dx.doi.org/10.1016/s0972-6292(16)30818-xDOI Listing

Publication Analysis

Top Keywords

dft testing
12
defibrillation threshold
8
arm abducted
8
abducted externally
8
externally rotated
8
arm
6
shoulder joint
4
joint dislocation
4
dislocation unusual
4
unusual complication
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!