Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: Transforaminal lumbar interbody fusion is a popular procedure used to achieve spondylodesis in patients with degenerative lumbar spinal diseases. We present a rare case of a patient with a set screw fracture with cage dislocation after an open transforaminal lumbar interbody fusion procedure. To the best of our knowledge, this case is the first of its kind to be reported.
Case Presentation: A 44-year-old Caucasian woman attended a follow-up appointment at our hospital 3 months after treatment for second-degree lumbar spondylolisthesis (L4/L5) and osteochondrosis (L5/S1) with transforaminal lumbar interbody fusion and dorsal spondylodesis. She complained of severe leg pain on the left side. Her physical examination revealed a normal neurological status, except for paresthesia of the entire left lower limb and at the ball of the left foot. Radiological imaging showed breaking of the set screws with cage dislocation. Surgical revision was then performed with exchange of the whole dorsal instrumentation and the dislocated cage. Six weeks post-operatively, the patient was seen again at our clinic without neurological complaints, except for decreased sensitivity on the dorsum of her left foot. The wound healing and radiological follow-up were uneventful.
Conclusions: Hardware-related complications are rarely seen in patients with open transforaminal lumbar interbody fusion, but must be kept in mind and can potentially cause severe neurological deficits.