Environmental contamination has become a serious problem to human and environmental health, as exposure to a wide range of possible contaminants continuously increases due to industrial and agricultural activities. Whole cell sensors have been proposed as a powerful tool to detect class-specific toxicants based upon their biological activity and bioavailability. We demonstrated a robust toxicant detection platform based on a bioluminescence whole cell sensor array biochip (LumiChip). LumiChip harbors an integrated temperature control and a 16-member sensor array, as well as a simple but highly efficient luminescence collection setup. On LumiChip, samples were infused in an oxygen-permeable microfluidic flow channel to reach the sensor array. Time-lapse changes in bioluminescence emitted by the array members were measured on a single window-removed linear charge-coupled device (CCD) commonly used in commercial industrial process control or in barcode readers. Removal of the protective window on the linear CCD allowed lens-free direct interfacing of LumiChip to the CCD surface for measurement with high light collection efficiency. Bioluminescence induced by simulated contamination events was detected within 15 to 45 minutes. The portable LumiSense system utilizing the linear CCD in combination with the miniaturized LumiChip is a promising potential platform for on-site environmental monitoring of toxicant contamination.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/c4lc01189a | DOI Listing |
Anal Chim Acta
January 2025
Shanghai University of Medicine & Health Sciences, Shanghai, 201318, China. Electronic address:
Metal-organic frameworks (MOFs) are porous, ordered arrays formed by coordination bonds between organic ligands and metal ions or clusters. The highly tunable properties of the MOF structure and performance make it possible to meet the needs of many applications. Conductive MOFs are essential in the domain of sensing due to their electrical conductivity, porosity, and catalytic properties, offering an effective platform for detection.
View Article and Find Full Text PDFJ Agric Food Chem
January 2025
State Key Laboratory of Natural Medicines, National R&D Center for Chinese Herbal Medicine Processing, School of Engineering, China Pharmaceutical University, Nanjing 210009, China.
Irritable bowel syndrome (IBS) is a globally prevalent functional gastrointestinal disorder frequently misdiagnosed due to overlapping symptoms with other diseases. Currently, there are no rapid and effective diagnostic or therapeutic approaches for IBS. Despite this, low-FODMAP diets (LFDs) have become a major dietary intervention strategy for symptom relief.
View Article and Find Full Text PDFJ Mater Chem B
January 2025
Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Raleigh, NC 27695, USA.
Despite the various benefits of chlorpromazine, its misuse and overdose may lead to severe side effects, therefore, creating a user-friendly point-of-care device for monitoring the levels of chlorpromazine drug to manage the potential side effects and ensure the effective and safe use of the medication is highly desired. In this report, we have demonstrated a simple and scalable manufacturing process for the development of a 3D-printed conducting microneedle array-based electrochemical point-of-care device for the minimally invasive sensing of chlorpromazine. We used an inkjet printer to print the carbon and silver ink onto a customized 3D-printed ultrasharp microneedle array for the preparation of counter, working, and reference electrodes.
View Article and Find Full Text PDFACS Sens
January 2025
State Key Laboratory of Optoelectronic Materials and Technologies, School of Electronics and Information Technology; Guangdong Province Key Laboratory of Display Material and Technology, Sun Yat-Sen University, Guangzhou 510006, China.
Gouty arthritis is one of the most common forms of inflammatory arthritis and has brought a significant burden on patients and society. Current strategies for managing gout primarily focus on long-term urate-lowering therapy. With the rapid advancement of point-of-care testing (POCT) technology, continuous monitoring of gout-related biomarkers like uric acid (UA) or inflammatory cytokines can provide rapid and personalized diagnosis for gout management.
View Article and Find Full Text PDFNpj Flex Electron
October 2024
Thayer School of Engineering, Dartmouth College, Hanover, NH, 03755, USA.
The integration of flexible electronics and photonics has the potential to create revolutionary technologies, yet it has been challenging to marry electronic and photonic components on a single polymer device, especially through high-volume manufacturing. Here, we present a robust, chiplet-level heterogeneous integration of polymer-based circuits (CHIP), where several post-fabricated, ultrathin, polymer electronic, and optoelectronic chiplets are vertically bonded into one single chip at room temperature and then shaped into application-specific form factors with monolithic Input/Output (I/O). As a demonstration, we applied this process and developed a flexible 3D-integrated optrode with high-density arrays of microelectrodes for electrical recording and micro light-emitting diodes (μLEDs) for optogenetic stimulation while with unprecedented integration of additional temperature sensors for bio-safe operations and shielding designs for optoelectronic artifact prevention.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!