Background: Image-guided navigation systems (IGS) grant excellent clinical and radiological results, minimizing risks correlated with spinal instrumentation. However, there is some concern regarding the real need for IGS and its indications.

Objective: To analyze the accuracy, technical aspect, and radiation exposure data of the principal IGS based on computed tomography (CT) imaging.

Methods: The data of all patients treated for spinal instrumentation with the aid of an IGS system from January 2003 to March 2013 were retrospectively analyzed. We defined 2 groups: group I with an IGS system based on a preoperative CT scan; group II relied on an intraoperative CT scan. Screw accuracy was assessed with a postoperative CT scan control. Radiation dosage for patients was defined by using the technical parameters and dose report data. Statistical analysis was performed using the Fisher exact test with a significance of 5% (P value < .05).

Results: Two thousand twenty patients and 11,144 screws were analyzed. Group I had 794 patients (4246 screws); the accuracy was 96.1%. Group II had 1226 patients (6898 screws) treated, with 98.5% accuracy (P = .001). The radiation dose analysis showed better results in group II, with significant reduction of the effective dose to the patient.

Conclusion: The IGS based on an intraoperative CT scan grants excellent results, eliminating the rate of reoperation for misplaced instrumentations (screws, plate, and cage) or for inadequate bone decompression. However, this technology cannot replace the surgical skills, experience, and knowledge necessary for spine surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1227/NEU.0000000000000587DOI Listing

Publication Analysis

Top Keywords

spinal instrumentation
8
igs based
8
igs system
8
intraoperative scan
8
igs
6
patients
5
group
5
computed tomography-based
4
tomography-based image-guided
4
image-guided system
4

Similar Publications

Background: Direct vertebral rotation (DVR) effectiveness in improving scoliosis correction outcomes remains unclear and requires further investigation.

Purpose: This study aimed to evaluate the effectiveness of short and extended fusion techniques using en-bloc DVR in correcting adolescent idiopathic scoliosis (AIS) classified as Lenke 5 curve (5C).

Materials And Methods: This retrospective study included 90 randomly selected AIS patients with Lenke 5C who underwent posterior spinal instrumentation surgery using en-bloc DVR between 2014 and 2021.

View Article and Find Full Text PDF

Background: Comparative studies of posterior lumbar interbody fusion with cortical bone trajectory and pedicle screw in older patients, particularly in those aged ≥ 80 years, are rare. This study aimed to retrospectively analyze the clinical and surgical outcomes following posterior lumbar interbody fusion with pedicle screw fixation compared to cortical bone trajectory in patients aged ≥ 80 years with degenerative lumbar spine disease.

Methods: We included 68 patients aged ≥ 80 years who underwent degenerative lumbar spinal surgery at our spine center between January 2011 and December 2020.

View Article and Find Full Text PDF

Background: Prone lateral spinal surgery for simultaneous lateral and posterior approaches has recently been proposed to facilitate surgical room efficiency. The purpose of this study is to evaluate the feasibility and outcomes of minimally invasive prone lateral spinal surgery using a rotatable radiolucent Jackson table.

Methods: From July 2021 to June 2023, a consecutive series of patients who received minimally invasive prone lateral spinal surgery for various etiologies by the same surgical team were reviewed.

View Article and Find Full Text PDF

Background: Robotic-assisted spinal surgery has reportedly improved the accuracy of instrumentation with smaller incisions, improving surgical outcomes and reducing hospital stay. However, robot-assisted spine surgery has thus far been confined to placement of pedicle screw instrumentation only. This pilot study aims to explore the feasibility of utilizing the Mazor™ X Stealth Edition (Medtronic, Sofamor Danek USA), robotic-arm platform in the minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) procedure inclusive of interbody cage placement, in our institution.

View Article and Find Full Text PDF

Anterior lumbar interbody fusion (ALIF) is an anterior surgical approach for interbody fusion in the lumbar spine which affords the surgeon unfettered access to the disc space and allows for release of the anterior longitudinal ligament and insertion of a large, lordotic interbody graft. Despite the benefits associated with ALIF when compared with other lumbar interbody fusion techniques, the ALIF approach is associated with a number of unique complications, and certain patient-specific criteria (e.g.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!