Background: New-generation drug-eluting coronary stents have reduced the risk of coronary events, especially in patients with complex disease or lesions. To what extent different stent platforms, polymers, and antiproliferative drugs affect outcomes, however, is unclear. We investigated the safety and efficacy of a third-generation stent by comparing a highly biocompatible durable-polymer-coated zotarolimus-eluting stent with a biodegradable-polymer-coated biolimus-eluting stent.
Methods: This open-label, randomised, multicentre, non-inferiority trial was done at three sites across western Denmark. All patients who presented with stable coronary artery disease or acute coronary syndromes and at least one coronary artery lesion (more than 50% stenosis) from March, 2011, to August, 2012, were assessed for eligibility. Patients were randomly assigned in a 1:1 ratio to receive either the durable-polymer zotarolimus-eluting stent or the biodegradable-polymer biolimus-eluting stent. The primary endpoint was a composite of safety (cardiac death and myocardial infarction not clearly attributable to a non-target lesion) and efficacy (target-lesion revascularisation) at 12 months, analysed by intention to treat. The trial was powered to assess non-inferiority of durable-polymer zotarolimus-eluting stent compared with the biodegradable-polymer biolimus-eluting stent with a predetermined non-inferiority margin of 0·025. This trial is registered with ClinicalTrials.gov, number NCT01956448.
Findings: Of 7103 screened, 1502 patients with 1883 lesions were assigned to receive the durable-polymer zotarolimus-eluting stent and 1497 patients with 1791 lesions to receive the biodegradable-polymer biolimus-eluting stent. 79 (5·3%) and 75 (5·0%) patients, respectively, met the primary endpoint (absolute risk difference 0·0025, upper limit of one-sided 95% CI 0·016%; p=0·004). The individual components of the primary endpoint did not differ significantly between stent types at 12 months.
Interpretation: The durable-polymer-coated zotarolimus-eluting stent was non-inferior to the biodegradable-polymer-coated biolimus-eluting stent in unselected patients.
Funding: Medtronic Cardiovascular and Biosensors Interventional Technologies.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/S0140-6736(14)61794-3 | DOI Listing |
J Am Heart Assoc
November 2024
Department of Cardiology, Tel Aviv Sourasky Medical Center, Affiliated with the School of Medicine Tel Aviv University Tel Aviv Israel.
Lancet
November 2024
Department of Medical Sciences, Cardiology, Uppsala University, Uppsala, Sweden; Uppsala Clinical Research Center, Uppsala University, Uppsala, Sweden.
Pharmacoecon Open
January 2025
Department of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Koningsplein 1, 7512 KZ, Enschede, The Netherlands.
Background And Objective: Evidence on health economic outcomes for percutaneous coronary intervention (PCI) comparing different contemporary drug-eluting stents (DES) with each other is scarce, as most previous randomised DES trials did not assess such aspects. This prespecified health economic evaluation of the Comparison of Biodegradable Polymer and Durable Polymer Drug-Eluting Stents in an All Comers Population (BIO-RESORT) trial aimed to compare at 3-year follow-up both health effects and costs of PCI with one of three new-generation drug-eluting stents (DES) in patients with obstructive coronary artery disease.
Methods: The randomised BIO-RESORT trial assessed in 3514 patients the ultrathin-strut biodegradable polymer Orsiro sirolimus-eluting stent (SES) and very-thin-strut Synergy everolimus-eluting (EES) stent versus the thin-strut durable polymer Resolute Integrity zotarolimus-eluting stent (ZES).
Interv Neuroradiol
October 2024
Department of Neurology, University of Chicago, Chicago, IL, USA.
Background: Acute ischemic stroke (AIS) due to intracranial atherosclerotic disease (ICAD) carries a high risk of recurrence despite aggressive medical management. The aim of our study is to present our initial experience with the Onyx Frontier™ balloon-mounted drug-eluting stent (Medtronic, Santa Rosa, CA) for AIS due to ICAD.
Methods: We conducted a multicenter retrospective cohort study describing the technical feasibility, safety, and performance of using the Onyx Frontier™ balloon-mounted drug-eluting stent in patients with acute intracranial vessel occlusion due to ICAD across three comprehensive stroke centers in the United States.
J Am Heart Assoc
October 2024
Severance Cardiovascular Hospital Yonsei University, College of Medicine Seoul South Korea.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!